According to the regulation of the calculation method of air pollutants emission form stationary sources, the pollutants emission concentration, flow rate, dilution gas concentration of the factory must corrected to the standard condition of 273K, 1 atm and dry base. There are three methods to detect the moisture, one is the on-line moisture analyzer, another is the moisture data from Relative Accuracy Test Audit and the other is that using the detection of dry and wet base of the dilution gas concentration to get the moisture percentage. Among the three methods, only the RATA detection moisture data has followed the standard method. There is no data quality assurance and control for the on-line moisture analyzer. According to clear the difference of the moisture data from on-line moisture analyzer and RATA process, we choose 3 municipal and hazardous waste incinerator from north, middle and south Taiwan, respectively. We calculated the data difference between on-line moisture analyzer and RATA. The results show that all the RA is in the range 10.7%~55.35% larger than the regulation 10% of 40CFR75 Appendance A.
| Translated title of the contribution | The Study of Water Correction of CEMS Data for Municipal and Hazardous Waste Incinerator |
|---|---|
| Original language | Chinese (Traditional) |
| Pages (from-to) | 59-69 |
| Number of pages | 11 |
| Journal | 燃燒季刊 = Combustion Quarterly |
| Issue number | 90 |
| Publication status | Published - 2015 Aug 1 |