3-Dimensional representation for PC12 cell growth characterization

Yi Yu Lu, Yu Jie Huang, Kuo-Sheng Cheng

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

In this study, a 3-dimensional representation is employed to characterize electrical property of the cell growth status for PC12. This can extend Electrical Bioimpedance Spectroscopy (EBIS) to multi-electrode application associated with position for increasing the special frequency. Traditionally, 2-dimensional Cole-Cole plot lack for the message of special frequency, especially in multi-electrode applications. A homemade multi-frequency bioimpedance system (MFBii) is integrated for measurement. Results revealed that the impedance between these electrode's pathways can be distinguished a difference from the 3D plot. The electrical property of biological object can be obtained by a set of Cole-Cole plots. This method could offer more information in cell growth, such as cell viability and proliferation monitoring.

Original languageEnglish
Title of host publication2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012
Pages688-691
Number of pages4
DOIs
Publication statusPublished - 2012 Dec 1
Event2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012 - Chongqing, China
Duration: 2012 Oct 162012 Oct 18

Publication series

Name2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012

Other

Other2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012
CountryChina
CityChongqing
Period12-10-1612-10-18

Fingerprint

PC12 Cells
Cell growth
Electrodes
Electric properties
Growth
Electric Impedance
Spectrum Analysis
Cell Survival
Cells
Cell Proliferation
Spectroscopy
Monitoring

All Science Journal Classification (ASJC) codes

  • Biomedical Engineering
  • Health Informatics

Cite this

Lu, Y. Y., Huang, Y. J., & Cheng, K-S. (2012). 3-Dimensional representation for PC12 cell growth characterization. In 2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012 (pp. 688-691). [6513001] (2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012). https://doi.org/10.1109/BMEI.2012.6513001
Lu, Yi Yu ; Huang, Yu Jie ; Cheng, Kuo-Sheng. / 3-Dimensional representation for PC12 cell growth characterization. 2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012. 2012. pp. 688-691 (2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012).
@inproceedings{e91d522435904ea0a26ff76ff854bdc3,
title = "3-Dimensional representation for PC12 cell growth characterization",
abstract = "In this study, a 3-dimensional representation is employed to characterize electrical property of the cell growth status for PC12. This can extend Electrical Bioimpedance Spectroscopy (EBIS) to multi-electrode application associated with position for increasing the special frequency. Traditionally, 2-dimensional Cole-Cole plot lack for the message of special frequency, especially in multi-electrode applications. A homemade multi-frequency bioimpedance system (MFBii) is integrated for measurement. Results revealed that the impedance between these electrode's pathways can be distinguished a difference from the 3D plot. The electrical property of biological object can be obtained by a set of Cole-Cole plots. This method could offer more information in cell growth, such as cell viability and proliferation monitoring.",
author = "Lu, {Yi Yu} and Huang, {Yu Jie} and Kuo-Sheng Cheng",
year = "2012",
month = "12",
day = "1",
doi = "10.1109/BMEI.2012.6513001",
language = "English",
isbn = "9781467311816",
series = "2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012",
pages = "688--691",
booktitle = "2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012",

}

Lu, YY, Huang, YJ & Cheng, K-S 2012, 3-Dimensional representation for PC12 cell growth characterization. in 2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012., 6513001, 2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012, pp. 688-691, 2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012, Chongqing, China, 12-10-16. https://doi.org/10.1109/BMEI.2012.6513001

3-Dimensional representation for PC12 cell growth characterization. / Lu, Yi Yu; Huang, Yu Jie; Cheng, Kuo-Sheng.

2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012. 2012. p. 688-691 6513001 (2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - 3-Dimensional representation for PC12 cell growth characterization

AU - Lu, Yi Yu

AU - Huang, Yu Jie

AU - Cheng, Kuo-Sheng

PY - 2012/12/1

Y1 - 2012/12/1

N2 - In this study, a 3-dimensional representation is employed to characterize electrical property of the cell growth status for PC12. This can extend Electrical Bioimpedance Spectroscopy (EBIS) to multi-electrode application associated with position for increasing the special frequency. Traditionally, 2-dimensional Cole-Cole plot lack for the message of special frequency, especially in multi-electrode applications. A homemade multi-frequency bioimpedance system (MFBii) is integrated for measurement. Results revealed that the impedance between these electrode's pathways can be distinguished a difference from the 3D plot. The electrical property of biological object can be obtained by a set of Cole-Cole plots. This method could offer more information in cell growth, such as cell viability and proliferation monitoring.

AB - In this study, a 3-dimensional representation is employed to characterize electrical property of the cell growth status for PC12. This can extend Electrical Bioimpedance Spectroscopy (EBIS) to multi-electrode application associated with position for increasing the special frequency. Traditionally, 2-dimensional Cole-Cole plot lack for the message of special frequency, especially in multi-electrode applications. A homemade multi-frequency bioimpedance system (MFBii) is integrated for measurement. Results revealed that the impedance between these electrode's pathways can be distinguished a difference from the 3D plot. The electrical property of biological object can be obtained by a set of Cole-Cole plots. This method could offer more information in cell growth, such as cell viability and proliferation monitoring.

UR - http://www.scopus.com/inward/record.url?scp=84886406596&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84886406596&partnerID=8YFLogxK

U2 - 10.1109/BMEI.2012.6513001

DO - 10.1109/BMEI.2012.6513001

M3 - Conference contribution

AN - SCOPUS:84886406596

SN - 9781467311816

T3 - 2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012

SP - 688

EP - 691

BT - 2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012

ER -

Lu YY, Huang YJ, Cheng K-S. 3-Dimensional representation for PC12 cell growth characterization. In 2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012. 2012. p. 688-691. 6513001. (2012 5th International Conference on Biomedical Engineering and Informatics, BMEI 2012). https://doi.org/10.1109/BMEI.2012.6513001