A microstructurally motivated model of the mechanical behavior of tissue engineered blood vessels

Shannon L.M. Dahl, Megann E. Vaughn, Jin-Jia Hu, Niels J.B. Driessen, Frank P.T. Baaijens, Jay D. Humphrey, Laura E. Niklason

Research output: Contribution to journalArticle

17 Citations (Scopus)

Abstract

Mechanical models have potential to guide the development and use of engineered blood vessels as well as other engineered tissues. This paper presents a microstructurally motivated, pseudoelastic, mechanical model of the biaxial mechanics of engineered vessels in the physiologic pressure range. The model incorporates experimentally measured densities and alignments of engineered collagen. Specifically, these microstructural and associated mechanical inputs were measured directly from engineered blood vessels that were cultured over periods of 5-7.5 weeks. To the best of our knowledge, this is the first successful application of either a phenomenological or a microstructurally motivated mechanical model to engineered vascular tissues. Model development revealed the need to use novel theoretical configurations to describe the strain history of engineered vessels. The constitutive equations developed herein suggested that collagen remodeled between 5 and 7.5 weeks during a 7.5-week culture period. This remodeling led to strain energies for collagen that differed with alignment, which likely resulted from undulations that varied with alignment. Finally, biaxial data emphasized that axial extensions increase stresses in engineered vessels in the physiologic pressure range, thereby providing a guideline for surgical use: engineered vessels should be implanted at appropriate axial extension to minimize adverse stress responses.

Original languageEnglish
Pages (from-to)1782-1792
Number of pages11
JournalAnnals of biomedical engineering
Volume36
Issue number11
DOIs
Publication statusPublished - 2008 Nov 1

Fingerprint

Blood vessels
Tissue
Collagen
Strain energy
Constitutive equations
Mechanics

All Science Journal Classification (ASJC) codes

  • Biomedical Engineering

Cite this

Dahl, S. L. M., Vaughn, M. E., Hu, J-J., Driessen, N. J. B., Baaijens, F. P. T., Humphrey, J. D., & Niklason, L. E. (2008). A microstructurally motivated model of the mechanical behavior of tissue engineered blood vessels. Annals of biomedical engineering, 36(11), 1782-1792. https://doi.org/10.1007/s10439-008-9554-4
Dahl, Shannon L.M. ; Vaughn, Megann E. ; Hu, Jin-Jia ; Driessen, Niels J.B. ; Baaijens, Frank P.T. ; Humphrey, Jay D. ; Niklason, Laura E. / A microstructurally motivated model of the mechanical behavior of tissue engineered blood vessels. In: Annals of biomedical engineering. 2008 ; Vol. 36, No. 11. pp. 1782-1792.
@article{dd4ce01972b44995947e4dafc665114d,
title = "A microstructurally motivated model of the mechanical behavior of tissue engineered blood vessels",
abstract = "Mechanical models have potential to guide the development and use of engineered blood vessels as well as other engineered tissues. This paper presents a microstructurally motivated, pseudoelastic, mechanical model of the biaxial mechanics of engineered vessels in the physiologic pressure range. The model incorporates experimentally measured densities and alignments of engineered collagen. Specifically, these microstructural and associated mechanical inputs were measured directly from engineered blood vessels that were cultured over periods of 5-7.5 weeks. To the best of our knowledge, this is the first successful application of either a phenomenological or a microstructurally motivated mechanical model to engineered vascular tissues. Model development revealed the need to use novel theoretical configurations to describe the strain history of engineered vessels. The constitutive equations developed herein suggested that collagen remodeled between 5 and 7.5 weeks during a 7.5-week culture period. This remodeling led to strain energies for collagen that differed with alignment, which likely resulted from undulations that varied with alignment. Finally, biaxial data emphasized that axial extensions increase stresses in engineered vessels in the physiologic pressure range, thereby providing a guideline for surgical use: engineered vessels should be implanted at appropriate axial extension to minimize adverse stress responses.",
author = "Dahl, {Shannon L.M.} and Vaughn, {Megann E.} and Jin-Jia Hu and Driessen, {Niels J.B.} and Baaijens, {Frank P.T.} and Humphrey, {Jay D.} and Niklason, {Laura E.}",
year = "2008",
month = "11",
day = "1",
doi = "10.1007/s10439-008-9554-4",
language = "English",
volume = "36",
pages = "1782--1792",
journal = "Annals of Biomedical Engineering",
issn = "0090-6964",
publisher = "Springer Netherlands",
number = "11",

}

Dahl, SLM, Vaughn, ME, Hu, J-J, Driessen, NJB, Baaijens, FPT, Humphrey, JD & Niklason, LE 2008, 'A microstructurally motivated model of the mechanical behavior of tissue engineered blood vessels', Annals of biomedical engineering, vol. 36, no. 11, pp. 1782-1792. https://doi.org/10.1007/s10439-008-9554-4

A microstructurally motivated model of the mechanical behavior of tissue engineered blood vessels. / Dahl, Shannon L.M.; Vaughn, Megann E.; Hu, Jin-Jia; Driessen, Niels J.B.; Baaijens, Frank P.T.; Humphrey, Jay D.; Niklason, Laura E.

In: Annals of biomedical engineering, Vol. 36, No. 11, 01.11.2008, p. 1782-1792.

Research output: Contribution to journalArticle

TY - JOUR

T1 - A microstructurally motivated model of the mechanical behavior of tissue engineered blood vessels

AU - Dahl, Shannon L.M.

AU - Vaughn, Megann E.

AU - Hu, Jin-Jia

AU - Driessen, Niels J.B.

AU - Baaijens, Frank P.T.

AU - Humphrey, Jay D.

AU - Niklason, Laura E.

PY - 2008/11/1

Y1 - 2008/11/1

N2 - Mechanical models have potential to guide the development and use of engineered blood vessels as well as other engineered tissues. This paper presents a microstructurally motivated, pseudoelastic, mechanical model of the biaxial mechanics of engineered vessels in the physiologic pressure range. The model incorporates experimentally measured densities and alignments of engineered collagen. Specifically, these microstructural and associated mechanical inputs were measured directly from engineered blood vessels that were cultured over periods of 5-7.5 weeks. To the best of our knowledge, this is the first successful application of either a phenomenological or a microstructurally motivated mechanical model to engineered vascular tissues. Model development revealed the need to use novel theoretical configurations to describe the strain history of engineered vessels. The constitutive equations developed herein suggested that collagen remodeled between 5 and 7.5 weeks during a 7.5-week culture period. This remodeling led to strain energies for collagen that differed with alignment, which likely resulted from undulations that varied with alignment. Finally, biaxial data emphasized that axial extensions increase stresses in engineered vessels in the physiologic pressure range, thereby providing a guideline for surgical use: engineered vessels should be implanted at appropriate axial extension to minimize adverse stress responses.

AB - Mechanical models have potential to guide the development and use of engineered blood vessels as well as other engineered tissues. This paper presents a microstructurally motivated, pseudoelastic, mechanical model of the biaxial mechanics of engineered vessels in the physiologic pressure range. The model incorporates experimentally measured densities and alignments of engineered collagen. Specifically, these microstructural and associated mechanical inputs were measured directly from engineered blood vessels that were cultured over periods of 5-7.5 weeks. To the best of our knowledge, this is the first successful application of either a phenomenological or a microstructurally motivated mechanical model to engineered vascular tissues. Model development revealed the need to use novel theoretical configurations to describe the strain history of engineered vessels. The constitutive equations developed herein suggested that collagen remodeled between 5 and 7.5 weeks during a 7.5-week culture period. This remodeling led to strain energies for collagen that differed with alignment, which likely resulted from undulations that varied with alignment. Finally, biaxial data emphasized that axial extensions increase stresses in engineered vessels in the physiologic pressure range, thereby providing a guideline for surgical use: engineered vessels should be implanted at appropriate axial extension to minimize adverse stress responses.

UR - http://www.scopus.com/inward/record.url?scp=54849411013&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=54849411013&partnerID=8YFLogxK

U2 - 10.1007/s10439-008-9554-4

DO - 10.1007/s10439-008-9554-4

M3 - Article

VL - 36

SP - 1782

EP - 1792

JO - Annals of Biomedical Engineering

JF - Annals of Biomedical Engineering

SN - 0090-6964

IS - 11

ER -