A multi-functional online measurement system for neuron-microelectrode interface study

C. K. Liang, D. K. Chen, Jia Jin J. Chen, S. C. Chen

Research output: Contribution to journalConference article

Abstract

The goal of this paper is to develop a multi-functional measurement system for neuron-microelectrode interface study by LabVIEW. The system uses a commercial 60-channel microelectrode array (MEA) as an interface platform. These online functions of neuronal stimulation, extracellular potential recording, impedance monitoring, and data storage have been integrated into this system. Two offline analysis functions of wavelet de-noising and artifact removing are also included. The former two online functions are executed respectively by a NI-DAQ card and by a self-made analog frond-end amplifier, and Agitent 4284A LCR meter makes the impedance measurement We have completed the basic functional verifications on a cultured MEA with PC-12.

Original languageEnglish
Pages (from-to)4100-4102
Number of pages3
JournalAnnual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
Volume26 VI
Publication statusPublished - 2004 Dec 1
EventConference Proceedings - 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2004 - San Francisco, CA, United States
Duration: 2004 Sep 12004 Sep 5

Fingerprint

Online Systems
Microelectrodes
Neurons
Electric Impedance
Wavelet Analysis
Information Storage and Retrieval
Artifacts
Data storage equipment
Monitoring

All Science Journal Classification (ASJC) codes

  • Signal Processing
  • Biomedical Engineering
  • Computer Vision and Pattern Recognition
  • Health Informatics

Cite this

@article{978aba8806a945c18b904b8dc26495cf,
title = "A multi-functional online measurement system for neuron-microelectrode interface study",
abstract = "The goal of this paper is to develop a multi-functional measurement system for neuron-microelectrode interface study by LabVIEW. The system uses a commercial 60-channel microelectrode array (MEA) as an interface platform. These online functions of neuronal stimulation, extracellular potential recording, impedance monitoring, and data storage have been integrated into this system. Two offline analysis functions of wavelet de-noising and artifact removing are also included. The former two online functions are executed respectively by a NI-DAQ card and by a self-made analog frond-end amplifier, and Agitent 4284A LCR meter makes the impedance measurement We have completed the basic functional verifications on a cultured MEA with PC-12.",
author = "Liang, {C. K.} and Chen, {D. K.} and Chen, {Jia Jin J.} and Chen, {S. C.}",
year = "2004",
month = "12",
day = "1",
language = "English",
volume = "26 VI",
pages = "4100--4102",
journal = "Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings",
issn = "1557-170X",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

A multi-functional online measurement system for neuron-microelectrode interface study. / Liang, C. K.; Chen, D. K.; Chen, Jia Jin J.; Chen, S. C.

In: Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings, Vol. 26 VI, 01.12.2004, p. 4100-4102.

Research output: Contribution to journalConference article

TY - JOUR

T1 - A multi-functional online measurement system for neuron-microelectrode interface study

AU - Liang, C. K.

AU - Chen, D. K.

AU - Chen, Jia Jin J.

AU - Chen, S. C.

PY - 2004/12/1

Y1 - 2004/12/1

N2 - The goal of this paper is to develop a multi-functional measurement system for neuron-microelectrode interface study by LabVIEW. The system uses a commercial 60-channel microelectrode array (MEA) as an interface platform. These online functions of neuronal stimulation, extracellular potential recording, impedance monitoring, and data storage have been integrated into this system. Two offline analysis functions of wavelet de-noising and artifact removing are also included. The former two online functions are executed respectively by a NI-DAQ card and by a self-made analog frond-end amplifier, and Agitent 4284A LCR meter makes the impedance measurement We have completed the basic functional verifications on a cultured MEA with PC-12.

AB - The goal of this paper is to develop a multi-functional measurement system for neuron-microelectrode interface study by LabVIEW. The system uses a commercial 60-channel microelectrode array (MEA) as an interface platform. These online functions of neuronal stimulation, extracellular potential recording, impedance monitoring, and data storage have been integrated into this system. Two offline analysis functions of wavelet de-noising and artifact removing are also included. The former two online functions are executed respectively by a NI-DAQ card and by a self-made analog frond-end amplifier, and Agitent 4284A LCR meter makes the impedance measurement We have completed the basic functional verifications on a cultured MEA with PC-12.

UR - http://www.scopus.com/inward/record.url?scp=11144342777&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=11144342777&partnerID=8YFLogxK

M3 - Conference article

AN - SCOPUS:11144342777

VL - 26 VI

SP - 4100

EP - 4102

JO - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

JF - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

SN - 1557-170X

ER -