A new dual channel pulse wave velocity measurement system

Yung Kang Chen, Hsien Tsai Wu, Chih Kai Chi, Wei-Chuan Tsai, Zi-Yi Chen, Ming Chun Wang

Research output: Chapter in Book/Report/Conference proceedingConference contribution

13 Citations (Scopus)

Abstract

Pulse wave velocity (PWV) is the most popular index to assessment the arterial stiffness. Currently, several non-invasive examination methods with single channel for PWV are announced. This paper proposes a non-invasive digital volume pulse (DVP) measuring system using a dual channel simultaneous measurement method try to meet the demands for home healthcare equipment which is easy to operate. Through synchronal technical in measuring DVP signals from finger and toe can achieves more precise time and substantially reduces the time spend in measurement procedures. In the other side, the proposed system developed an algorithm to locate the "Foot of the wave" without facilitating of electrocardiogram (ECG).

Original languageEnglish
Title of host publicationProceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004
Pages17-21
Number of pages5
DOIs
Publication statusPublished - 2004 Sep 24
EventProceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004 - Taichung, Taiwan
Duration: 2004 May 192004 May 21

Publication series

NameProceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004

Other

OtherProceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004
CountryTaiwan
CityTaichung
Period04-05-1904-05-21

Fingerprint

Velocity measurement
Electrocardiography
Stiffness

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Cite this

Chen, Y. K., Wu, H. T., Chi, C. K., Tsai, W-C., Chen, Z-Y., & Wang, M. C. (2004). A new dual channel pulse wave velocity measurement system. In Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004 (pp. 17-21). (Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004). https://doi.org/10.1016/S0030-5898(03)00052-X
Chen, Yung Kang ; Wu, Hsien Tsai ; Chi, Chih Kai ; Tsai, Wei-Chuan ; Chen, Zi-Yi ; Wang, Ming Chun. / A new dual channel pulse wave velocity measurement system. Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004. 2004. pp. 17-21 (Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004).
@inproceedings{5ac030ec6e754255ae15db872dbf03d7,
title = "A new dual channel pulse wave velocity measurement system",
abstract = "Pulse wave velocity (PWV) is the most popular index to assessment the arterial stiffness. Currently, several non-invasive examination methods with single channel for PWV are announced. This paper proposes a non-invasive digital volume pulse (DVP) measuring system using a dual channel simultaneous measurement method try to meet the demands for home healthcare equipment which is easy to operate. Through synchronal technical in measuring DVP signals from finger and toe can achieves more precise time and substantially reduces the time spend in measurement procedures. In the other side, the proposed system developed an algorithm to locate the {"}Foot of the wave{"} without facilitating of electrocardiogram (ECG).",
author = "Chen, {Yung Kang} and Wu, {Hsien Tsai} and Chi, {Chih Kai} and Wei-Chuan Tsai and Zi-Yi Chen and Wang, {Ming Chun}",
year = "2004",
month = "9",
day = "24",
doi = "10.1016/S0030-5898(03)00052-X",
language = "English",
isbn = "0769521738",
series = "Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004",
pages = "17--21",
booktitle = "Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004",

}

Chen, YK, Wu, HT, Chi, CK, Tsai, W-C, Chen, Z-Y & Wang, MC 2004, A new dual channel pulse wave velocity measurement system. in Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004. Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004, pp. 17-21, Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004, Taichung, Taiwan, 04-05-19. https://doi.org/10.1016/S0030-5898(03)00052-X

A new dual channel pulse wave velocity measurement system. / Chen, Yung Kang; Wu, Hsien Tsai; Chi, Chih Kai; Tsai, Wei-Chuan; Chen, Zi-Yi; Wang, Ming Chun.

Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004. 2004. p. 17-21 (Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - A new dual channel pulse wave velocity measurement system

AU - Chen, Yung Kang

AU - Wu, Hsien Tsai

AU - Chi, Chih Kai

AU - Tsai, Wei-Chuan

AU - Chen, Zi-Yi

AU - Wang, Ming Chun

PY - 2004/9/24

Y1 - 2004/9/24

N2 - Pulse wave velocity (PWV) is the most popular index to assessment the arterial stiffness. Currently, several non-invasive examination methods with single channel for PWV are announced. This paper proposes a non-invasive digital volume pulse (DVP) measuring system using a dual channel simultaneous measurement method try to meet the demands for home healthcare equipment which is easy to operate. Through synchronal technical in measuring DVP signals from finger and toe can achieves more precise time and substantially reduces the time spend in measurement procedures. In the other side, the proposed system developed an algorithm to locate the "Foot of the wave" without facilitating of electrocardiogram (ECG).

AB - Pulse wave velocity (PWV) is the most popular index to assessment the arterial stiffness. Currently, several non-invasive examination methods with single channel for PWV are announced. This paper proposes a non-invasive digital volume pulse (DVP) measuring system using a dual channel simultaneous measurement method try to meet the demands for home healthcare equipment which is easy to operate. Through synchronal technical in measuring DVP signals from finger and toe can achieves more precise time and substantially reduces the time spend in measurement procedures. In the other side, the proposed system developed an algorithm to locate the "Foot of the wave" without facilitating of electrocardiogram (ECG).

UR - http://www.scopus.com/inward/record.url?scp=4544308347&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=4544308347&partnerID=8YFLogxK

U2 - 10.1016/S0030-5898(03)00052-X

DO - 10.1016/S0030-5898(03)00052-X

M3 - Conference contribution

AN - SCOPUS:4544308347

SN - 0769521738

SN - 9780769521732

T3 - Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004

SP - 17

EP - 21

BT - Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004

ER -

Chen YK, Wu HT, Chi CK, Tsai W-C, Chen Z-Y, Wang MC. A new dual channel pulse wave velocity measurement system. In Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004. 2004. p. 17-21. (Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004). https://doi.org/10.1016/S0030-5898(03)00052-X