A study on signal quality of a vortex flowmeter downstream of two elbows out-of-plane

J. J. Miau, C. W. Wu, C. C. Hu, J. H. Chou

Research output: Contribution to journalArticle

23 Citations (Scopus)

Abstract

Experiments were made with a vortex meter situated downstream of two elbows out-of-plane, at Reynolds numbers between 7.8 × 104 and 2.1 × 105. Analysis on the signals obtained from a piezo-electric sensor embedded in the vortex shedder shows that the signal quality, concerned with the vortex shedding frequency component, deduced in the vicinity of 15 pipe diameters downstream is superior to that at other locations, and is remarkably better than that found in the region of fully-developed turbulent pipe flow. The vortex shedding frequencies measured in this region, in terms of the Strouhal value, fall within 0.129 ± 0.001, that 0.129 is the reference value reduced in the fully-developed turbulent pipe flow region. Also noted, the uncertainty interval associated with the vortex shedding frequency measured in this region is smaller than that reduced in the region of fully-developed turbulent pipe flow.

Original languageEnglish
Pages (from-to)75-85
Number of pages11
JournalFlow Measurement and Instrumentation
Volume13
Issue number3
DOIs
Publication statusPublished - 2002 Jun 1

All Science Journal Classification (ASJC) codes

  • Modelling and Simulation
  • Instrumentation
  • Computer Science Applications
  • Electrical and Electronic Engineering

Fingerprint Dive into the research topics of 'A study on signal quality of a vortex flowmeter downstream of two elbows out-of-plane'. Together they form a unique fingerprint.

  • Cite this