T1 - A Study on the Structure and Biomedical Application Characteristics of Phosphate Coatings on ZKX500 Magnesium Alloys
AU - Huang, Ying Ting
AU - Wu, Wen Yu
AU - Hung, Fei Yi
AU - Kuan, Fa Chuan
AU - Hsu, Kai Lan
AU - Su, Wei Ren
AU - Yen, Chen Wei
N1 - Funding Information:
The authors are grateful to Taiwan TING SIN Co., Ltd. and Lin, Chia-Yu of the Core Facility Center of NCKU for TEM measurements, JEM-2100F STEM equipment belonging to the Core Facility Center of National Cheng Kung University, and the Ministry of Science and Technology of Taiwan, 108-2221-E-006-140-MY3, for their financial support.
Publisher Copyright:
© 2022 by the authors.
PY - 2022/10
Y1 - 2022/10
N2 - Magnesium-matrix implants can be detected by X-ray, making post-operative monitoring easier. Since the density and mechanical properties of Mg alloys are similar to those of human bones, the stress-shielding effect can be avoided, accelerating the recovery and regeneration of bone tissues. Additionally, Mg biodegradability shields patients from the infection risk and medical financial burden of needing another surgery. However, the major challenge for magnesium-matrix implants is the rapid degradation rate, which necessitates surface treatment. In this study, the ZKX500 Mg alloy was used, and a non-toxic and eco-friendly anodic oxidation method was adopted to improve corrosion resistance. The results indicate that the anodic coating mainly consisted of magnesium phosphate. After anodic oxidation, the specimen surface developed a coating and an ion-exchanged layer that could slow down the degradation and help maintain the mechanical properties. The results of the tensile and impact tests reveal that after being immersed in SBF for 28 days, the anodic oxidation-treated specimens maintained good strength, ductility, and toughness. Anodic coating provides an excellent surface for cell attachment and growth. In the animal experiment, the anodic oxidation-treated magnesium bone screw used had no adverse effect and could support the injured part for at least 3 months.
AB - Magnesium-matrix implants can be detected by X-ray, making post-operative monitoring easier. Since the density and mechanical properties of Mg alloys are similar to those of human bones, the stress-shielding effect can be avoided, accelerating the recovery and regeneration of bone tissues. Additionally, Mg biodegradability shields patients from the infection risk and medical financial burden of needing another surgery. However, the major challenge for magnesium-matrix implants is the rapid degradation rate, which necessitates surface treatment. In this study, the ZKX500 Mg alloy was used, and a non-toxic and eco-friendly anodic oxidation method was adopted to improve corrosion resistance. The results indicate that the anodic coating mainly consisted of magnesium phosphate. After anodic oxidation, the specimen surface developed a coating and an ion-exchanged layer that could slow down the degradation and help maintain the mechanical properties. The results of the tensile and impact tests reveal that after being immersed in SBF for 28 days, the anodic oxidation-treated specimens maintained good strength, ductility, and toughness. Anodic coating provides an excellent surface for cell attachment and growth. In the animal experiment, the anodic oxidation-treated magnesium bone screw used had no adverse effect and could support the injured part for at least 3 months.
UR - http://www.scopus.com/inward/record.url?scp=85140456767&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85140456767&partnerID=8YFLogxK
U2 - 10.3390/bioengineering9100542
DO - 10.3390/bioengineering9100542
M3 - Article
AN - SCOPUS:85140456767
SN - 2306-5354
VL - 9
JO - Bioengineering
JF - Bioengineering
IS - 10
M1 - 542
ER -