T1 - Alterations in Respiratory Mechanics in Mechanically Ventilated Patients Following Bronchoalveolar Lavage
AU - Chou, Meng Yi
AU - Ou, Chih Ying
AU - Chen, Chang Wen
N1 - Funding Information:
This study was supported by a grant (NCKUH-96-065) from National Cheng-Kung University Medical Center.
PY - 2009/9
Y1 - 2009/9
N2 - Background/Purpose: Bronchoalveolar lavage (BAL) can be used for a variety of diagnostic purposes in mechanically ventilated patients. BAL can cause changes in respiratory mechanics. However, the risk factors associated with these changes remain unknown. The current study tried to identify the risk factors that contribute to changes in respiratory mechanics following BAL. Methods: Changes in respiratory mechanics were assessed in 56 mechanically ventilated patients who received BAL using an interrupter method under constant flow. Results: Intrinsic positive end-expiratory pressure (PEEPi) was correlated significantly with changes in respiratory system resistance and compliance following BAL in mechanically ventilated patients (p = 0.003). In 14 patients with PEEPi > 1 cmH2O, maximal resistance (Rmax) before BAL was 22.5 ± 5.9 cmH2O/L/S, increasing to 31.6 ± 8.5 cmH2O/L/S immediately after BAL, and remaining high (28.4 ± 7.5 cmH2O/L/S) 30 minutes later (p < 0.001). Increase in minimal resistance (Rmin), delta resistance (ΔR), and decrease in compliance followed the same time trend. In 42 patients with PEEPi £ 1 cmH2O, Rmax before BAL was 15.5 ± 3.5 cmH2O/L/S, increasing to 17.6 ± 4.6 cmH2O/L/S immediately after BAL, and decreasing to 16.6 ± 4.3 cmH2O/L/S (p < 0.001) 30 minutes later. Increase in Rmin, ΔR and decrease in compliance were similar to those seen with Rmax. Increases in Rmax, Rmin and ΔR, and decrease in compliance following BAL were significantly higher in patients with significant PEEPi than in those without throughout the recording period (p < 0.001). Conclusion: Patients with significant PEEPi experienced greater changes in respiratory mechanics than those without. Physicians should be cautious when performing BAL in such patients.
AB - Background/Purpose: Bronchoalveolar lavage (BAL) can be used for a variety of diagnostic purposes in mechanically ventilated patients. BAL can cause changes in respiratory mechanics. However, the risk factors associated with these changes remain unknown. The current study tried to identify the risk factors that contribute to changes in respiratory mechanics following BAL. Methods: Changes in respiratory mechanics were assessed in 56 mechanically ventilated patients who received BAL using an interrupter method under constant flow. Results: Intrinsic positive end-expiratory pressure (PEEPi) was correlated significantly with changes in respiratory system resistance and compliance following BAL in mechanically ventilated patients (p = 0.003). In 14 patients with PEEPi > 1 cmH2O, maximal resistance (Rmax) before BAL was 22.5 ± 5.9 cmH2O/L/S, increasing to 31.6 ± 8.5 cmH2O/L/S immediately after BAL, and remaining high (28.4 ± 7.5 cmH2O/L/S) 30 minutes later (p < 0.001). Increase in minimal resistance (Rmin), delta resistance (ΔR), and decrease in compliance followed the same time trend. In 42 patients with PEEPi £ 1 cmH2O, Rmax before BAL was 15.5 ± 3.5 cmH2O/L/S, increasing to 17.6 ± 4.6 cmH2O/L/S immediately after BAL, and decreasing to 16.6 ± 4.3 cmH2O/L/S (p < 0.001) 30 minutes later. Increase in Rmin, ΔR and decrease in compliance were similar to those seen with Rmax. Increases in Rmax, Rmin and ΔR, and decrease in compliance following BAL were significantly higher in patients with significant PEEPi than in those without throughout the recording period (p < 0.001). Conclusion: Patients with significant PEEPi experienced greater changes in respiratory mechanics than those without. Physicians should be cautious when performing BAL in such patients.
UR - http://www.scopus.com/inward/record.url?scp=71549171888&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=71549171888&partnerID=8YFLogxK
U2 - 10.1016/S0929-6646(09)60393-4
DO - 10.1016/S0929-6646(09)60393-4
M3 - Article
C2 - 19773208
AN - SCOPUS:71549171888
SN - 0929-6646
VL - 108
SP - 704
EP - 712
JO - Journal of the Formosan Medical Association
JF - Journal of the Formosan Medical Association
IS - 9
ER -