T1 - An integrated microfluidic system for measurement of glycated hemoglobin Levels by using an aptamer-antibody assay on magnetic beads
AU - Chang, Ko Wei
AU - Li, Jinglun
AU - Yang, Ching Hsuan
AU - Shiesh, Shu Chu
AU - Lee, Gwo Bin
N1 - Funding Information:
The authors gratefully acknowledge the financial support provided by the National Science Council of Taiwan ( NSC102-2218-E-007-001 ). Partial financial support from the “ Towards a World-Class University ” ( 103N2048E1 ) Project is also greatly appreciated.
PY - 2015/6/5
Y1 - 2015/6/5
N2 - Blood glycated hemoglobin (HbA1c), reflecting the average blood glucose level in the proceeding 2-3 months, is recommended for screening/diagnosing and patient management of diabetes. However, accurate measurement of the HbA1c level at the point of care is hampered by costly, large-scale instruments (such as high-performance liquid chromatography) or reagent instability of classical immunologic methods, which involve antibody-based immunoturbidimetry. In this work, an integrated microfluidic system using aptamer-based testing to measure HbA1c in blood samples is therefore presented. This measuring system used nucleic-acid aptamers that exhibited high sensitivity and high specificity for hemoglobin and HbA1c to perform a stable and robust testing. The compact microfluidic system consumed less samples and reagents and significantly shortened the detection time. Combining the advantages of microfluidics and aptamers, this integrated microsystem presents a promising tool for accurate and point-of-case HbA1c detection. To demonstrate its clinical utility, whole blood samples with clinically-relevant concentrations of HbA1c and Hb were automatically measured on the integrated microfluidic system. Experimental data showed that the developed aptamer-based microfluidic system is capable of detecting HbA1c and Hb with a good linear response. The entire process was completed within 25. min. The aptamer-antibody on-chip sandwich immunoassay may be further refined to allow diabetes screening and diagnosis at lower cost and earlier phase to minimize the risk of diabetic complications.
AB - Blood glycated hemoglobin (HbA1c), reflecting the average blood glucose level in the proceeding 2-3 months, is recommended for screening/diagnosing and patient management of diabetes. However, accurate measurement of the HbA1c level at the point of care is hampered by costly, large-scale instruments (such as high-performance liquid chromatography) or reagent instability of classical immunologic methods, which involve antibody-based immunoturbidimetry. In this work, an integrated microfluidic system using aptamer-based testing to measure HbA1c in blood samples is therefore presented. This measuring system used nucleic-acid aptamers that exhibited high sensitivity and high specificity for hemoglobin and HbA1c to perform a stable and robust testing. The compact microfluidic system consumed less samples and reagents and significantly shortened the detection time. Combining the advantages of microfluidics and aptamers, this integrated microsystem presents a promising tool for accurate and point-of-case HbA1c detection. To demonstrate its clinical utility, whole blood samples with clinically-relevant concentrations of HbA1c and Hb were automatically measured on the integrated microfluidic system. Experimental data showed that the developed aptamer-based microfluidic system is capable of detecting HbA1c and Hb with a good linear response. The entire process was completed within 25. min. The aptamer-antibody on-chip sandwich immunoassay may be further refined to allow diabetes screening and diagnosis at lower cost and earlier phase to minimize the risk of diabetic complications.
UR - http://www.scopus.com/inward/record.url?scp=84921459521&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84921459521&partnerID=8YFLogxK
U2 - 10.1016/j.bios.2015.01.027
DO - 10.1016/j.bios.2015.01.027
M3 - Article
C2 - 25618372
AN - SCOPUS:84921459521
VL - 68
SP - 397
EP - 403
JO - Biosensors and Bioelectronics
JF - Biosensors and Bioelectronics
SN - 0956-5663
ER -