Aiming the application of localized hyperthermia, a magnetic induction system with new approaches is proposed. The techniques in this system for improving the effectiveness of localized hyperthermia are that using magnetic circuit and the multiple-coil array instead of a giant coil for generating magnetic field. Specially, amorphous metal is adopted as the material of magnetic circuit. Detail design parameters of hardware are well described. Simulation tool is employed for this work and experiment result is reported as well.

Original languageEnglish
Pages (from-to)724-727
Number of pages4
JournalWorld Academy of Science, Engineering and Technology
Volume58
Publication statusPublished - 2009 Oct 1

Fingerprint

Induction heating
Magnetic circuits
Electromagnetic induction
Magnetic fields
Hardware
Metals
Experiments

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Cite this

@article{f0dbfc3a32734e97b03e4485ced33413,
title = "Application of magnetic circuit and multiple-coils array in induction heating for improving localized hyperthermia",
abstract = "Aiming the application of localized hyperthermia, a magnetic induction system with new approaches is proposed. The techniques in this system for improving the effectiveness of localized hyperthermia are that using magnetic circuit and the multiple-coil array instead of a giant coil for generating magnetic field. Specially, amorphous metal is adopted as the material of magnetic circuit. Detail design parameters of hardware are well described. Simulation tool is employed for this work and experiment result is reported as well.",
author = "Huang, {Chi Fang} and Xi-Zhang Lin and Yang, {Yi Ru}",
year = "2009",
month = "10",
day = "1",
language = "English",
volume = "58",
pages = "724--727",
journal = "World Academy of Science, Engineering and Technology",
issn = "2010-376X",
publisher = "World Academy of Science Engineering and Technology",

}

Application of magnetic circuit and multiple-coils array in induction heating for improving localized hyperthermia. / Huang, Chi Fang; Lin, Xi-Zhang; Yang, Yi Ru.

In: World Academy of Science, Engineering and Technology, Vol. 58, 01.10.2009, p. 724-727.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Application of magnetic circuit and multiple-coils array in induction heating for improving localized hyperthermia

AU - Huang, Chi Fang

AU - Lin, Xi-Zhang

AU - Yang, Yi Ru

PY - 2009/10/1

Y1 - 2009/10/1

N2 - Aiming the application of localized hyperthermia, a magnetic induction system with new approaches is proposed. The techniques in this system for improving the effectiveness of localized hyperthermia are that using magnetic circuit and the multiple-coil array instead of a giant coil for generating magnetic field. Specially, amorphous metal is adopted as the material of magnetic circuit. Detail design parameters of hardware are well described. Simulation tool is employed for this work and experiment result is reported as well.

AB - Aiming the application of localized hyperthermia, a magnetic induction system with new approaches is proposed. The techniques in this system for improving the effectiveness of localized hyperthermia are that using magnetic circuit and the multiple-coil array instead of a giant coil for generating magnetic field. Specially, amorphous metal is adopted as the material of magnetic circuit. Detail design parameters of hardware are well described. Simulation tool is employed for this work and experiment result is reported as well.

UR - http://www.scopus.com/inward/record.url?scp=79954484115&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79954484115&partnerID=8YFLogxK

M3 - Article

VL - 58

SP - 724

EP - 727

JO - World Academy of Science, Engineering and Technology

JF - World Academy of Science, Engineering and Technology

SN - 2010-376X

ER -