T1 - Comparison of Osseointegration on Various Implant Surfaces After Bacterial Contamination and Cleaning
T2 - A Rabbit Study
AU - Yuan, Kuo
AU - Kung, Kuan Chen
AU - Lee, Tzer Min
N1 - Publisher Copyright:
© 2014. Quintessence Publishing Co Inc. All Rights Reserved.
PY - 2014
Y1 - 2014
N2 - Purpose: To examine the osseointegration of various implant surfaces after bacterial contamination and cleaning. Materials and Methods: Four types of implant surface were manufactured: machined (M); plasmaspray hydroxyapaptite (HA); sandblasted, large-grit, acid-etched (SA); and titanium anodic oxide (TAO) were manufactured. The surface characteristics of these implants were determined using a scanning electron microscope, an energy dispersive spectrometer, and a contact profilometer. Each surface was subdivided into control and test groups. Test implants were co-incubated with Prevotella intermedia for 2 weeks, then cleaned with cotton pellets, soaked in saline, and irrigated. Control implants underwent the same cleaning procedure, but without bacterial contamination. Four control or test implants with different surface types were randomly inserted into the tibia of 10 New Zealand white rabbits. After 6 weeks of healing, 5 rabbits were sacrificed for histomorphometry, and the rest for removal torque assay. Results: Bacterial contamination adversely influenced every implant surface in terms of bone-to-implant contact (BIC) ratio and required removal torque. The negative results reached significant levels for rougher surfaces (HA and SA). For both contaminated and uncontaminated samples, HA and SA implants required significantly higher removal torque than that required for M implants. Conclusion: Bacterial contamination jeopardized osseointegration on every tested implant surface. A more negative effect on BIC was found for implants with rougher surfaces. However, contaminated rough-surfaced implants showed more removal torque resistance than contaminated smooth implants. Int J Oral Maxiilofac Implants 2014;29:32-40. doi: 1O.116O7/jomi.2436
AB - Purpose: To examine the osseointegration of various implant surfaces after bacterial contamination and cleaning. Materials and Methods: Four types of implant surface were manufactured: machined (M); plasmaspray hydroxyapaptite (HA); sandblasted, large-grit, acid-etched (SA); and titanium anodic oxide (TAO) were manufactured. The surface characteristics of these implants were determined using a scanning electron microscope, an energy dispersive spectrometer, and a contact profilometer. Each surface was subdivided into control and test groups. Test implants were co-incubated with Prevotella intermedia for 2 weeks, then cleaned with cotton pellets, soaked in saline, and irrigated. Control implants underwent the same cleaning procedure, but without bacterial contamination. Four control or test implants with different surface types were randomly inserted into the tibia of 10 New Zealand white rabbits. After 6 weeks of healing, 5 rabbits were sacrificed for histomorphometry, and the rest for removal torque assay. Results: Bacterial contamination adversely influenced every implant surface in terms of bone-to-implant contact (BIC) ratio and required removal torque. The negative results reached significant levels for rougher surfaces (HA and SA). For both contaminated and uncontaminated samples, HA and SA implants required significantly higher removal torque than that required for M implants. Conclusion: Bacterial contamination jeopardized osseointegration on every tested implant surface. A more negative effect on BIC was found for implants with rougher surfaces. However, contaminated rough-surfaced implants showed more removal torque resistance than contaminated smooth implants. Int J Oral Maxiilofac Implants 2014;29:32-40. doi: 1O.116O7/jomi.2436
UR - http://www.scopus.com/inward/record.url?scp=84900029872&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84900029872&partnerID=8YFLogxK
U2 - 10.11607/jomi.2436
DO - 10.11607/jomi.2436
M3 - Article
C2 - 24451851
AN - SCOPUS:84900029872
SN - 0882-2786
VL - 29
SP - 32
EP - 40
JO - International Journal of Oral and Maxillofacial Implants
JF - International Journal of Oral and Maxillofacial Implants
IS - 1
ER -