Design considerations and clinical applications of closed-loop neural disorder control SoCs

Chung Yu Wu, Cheng Hsiang Cheng, Yi Huan Ou-Yang, Chiung Chu Chen, Wei Ming Chen, Ming Dou Ker, Chen Yi Lee, Sheng-Fu Liang, Fu-Zen Shaw

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

This paper presents the closed-loop neural disorder control concept and some design considerations. Two architectures of closed-loop neuromodulation for Parkinson's disease and epileptic seizure are proposed. One is a closed-loop deep brain stimulator, which meets the IEC 60601-1 standard. The other one is an implantable SoC for epileptic seizure control, which is verified by animal experiment.

Original languageEnglish
Title of host publication2017 22nd Asia and South Pacific Design Automation Conference, ASP-DAC 2017
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages295-298
Number of pages4
ISBN (Electronic)9781509015580
DOIs
Publication statusPublished - 2017 Feb 16
Event22nd Asia and South Pacific Design Automation Conference, ASP-DAC 2017 - Chiba, Japan
Duration: 2017 Jan 162017 Jan 19

Publication series

NameProceedings of the Asia and South Pacific Design Automation Conference, ASP-DAC

Other

Other22nd Asia and South Pacific Design Automation Conference, ASP-DAC 2017
CountryJapan
CityChiba
Period17-01-1617-01-19

Fingerprint

Brain
Animals
Experiments
System-on-chip

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering
  • Computer Science Applications
  • Computer Graphics and Computer-Aided Design

Cite this

Wu, C. Y., Cheng, C. H., Ou-Yang, Y. H., Chen, C. C., Chen, W. M., Ker, M. D., ... Shaw, F-Z. (2017). Design considerations and clinical applications of closed-loop neural disorder control SoCs. In 2017 22nd Asia and South Pacific Design Automation Conference, ASP-DAC 2017 (pp. 295-298). [7858337] (Proceedings of the Asia and South Pacific Design Automation Conference, ASP-DAC). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/ASPDAC.2017.7858337
Wu, Chung Yu ; Cheng, Cheng Hsiang ; Ou-Yang, Yi Huan ; Chen, Chiung Chu ; Chen, Wei Ming ; Ker, Ming Dou ; Lee, Chen Yi ; Liang, Sheng-Fu ; Shaw, Fu-Zen. / Design considerations and clinical applications of closed-loop neural disorder control SoCs. 2017 22nd Asia and South Pacific Design Automation Conference, ASP-DAC 2017. Institute of Electrical and Electronics Engineers Inc., 2017. pp. 295-298 (Proceedings of the Asia and South Pacific Design Automation Conference, ASP-DAC).
@inproceedings{9b45ed628a7e499c8193ac0ce1c5809f,
title = "Design considerations and clinical applications of closed-loop neural disorder control SoCs",
abstract = "This paper presents the closed-loop neural disorder control concept and some design considerations. Two architectures of closed-loop neuromodulation for Parkinson's disease and epileptic seizure are proposed. One is a closed-loop deep brain stimulator, which meets the IEC 60601-1 standard. The other one is an implantable SoC for epileptic seizure control, which is verified by animal experiment.",
author = "Wu, {Chung Yu} and Cheng, {Cheng Hsiang} and Ou-Yang, {Yi Huan} and Chen, {Chiung Chu} and Chen, {Wei Ming} and Ker, {Ming Dou} and Lee, {Chen Yi} and Sheng-Fu Liang and Fu-Zen Shaw",
year = "2017",
month = "2",
day = "16",
doi = "10.1109/ASPDAC.2017.7858337",
language = "English",
series = "Proceedings of the Asia and South Pacific Design Automation Conference, ASP-DAC",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
pages = "295--298",
booktitle = "2017 22nd Asia and South Pacific Design Automation Conference, ASP-DAC 2017",
address = "United States",

}

Wu, CY, Cheng, CH, Ou-Yang, YH, Chen, CC, Chen, WM, Ker, MD, Lee, CY, Liang, S-F & Shaw, F-Z 2017, Design considerations and clinical applications of closed-loop neural disorder control SoCs. in 2017 22nd Asia and South Pacific Design Automation Conference, ASP-DAC 2017., 7858337, Proceedings of the Asia and South Pacific Design Automation Conference, ASP-DAC, Institute of Electrical and Electronics Engineers Inc., pp. 295-298, 22nd Asia and South Pacific Design Automation Conference, ASP-DAC 2017, Chiba, Japan, 17-01-16. https://doi.org/10.1109/ASPDAC.2017.7858337

Design considerations and clinical applications of closed-loop neural disorder control SoCs. / Wu, Chung Yu; Cheng, Cheng Hsiang; Ou-Yang, Yi Huan; Chen, Chiung Chu; Chen, Wei Ming; Ker, Ming Dou; Lee, Chen Yi; Liang, Sheng-Fu; Shaw, Fu-Zen.

2017 22nd Asia and South Pacific Design Automation Conference, ASP-DAC 2017. Institute of Electrical and Electronics Engineers Inc., 2017. p. 295-298 7858337 (Proceedings of the Asia and South Pacific Design Automation Conference, ASP-DAC).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - Design considerations and clinical applications of closed-loop neural disorder control SoCs

AU - Wu, Chung Yu

AU - Cheng, Cheng Hsiang

AU - Ou-Yang, Yi Huan

AU - Chen, Chiung Chu

AU - Chen, Wei Ming

AU - Ker, Ming Dou

AU - Lee, Chen Yi

AU - Liang, Sheng-Fu

AU - Shaw, Fu-Zen

PY - 2017/2/16

Y1 - 2017/2/16

N2 - This paper presents the closed-loop neural disorder control concept and some design considerations. Two architectures of closed-loop neuromodulation for Parkinson's disease and epileptic seizure are proposed. One is a closed-loop deep brain stimulator, which meets the IEC 60601-1 standard. The other one is an implantable SoC for epileptic seizure control, which is verified by animal experiment.

AB - This paper presents the closed-loop neural disorder control concept and some design considerations. Two architectures of closed-loop neuromodulation for Parkinson's disease and epileptic seizure are proposed. One is a closed-loop deep brain stimulator, which meets the IEC 60601-1 standard. The other one is an implantable SoC for epileptic seizure control, which is verified by animal experiment.

UR - http://www.scopus.com/inward/record.url?scp=85015266925&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85015266925&partnerID=8YFLogxK

U2 - 10.1109/ASPDAC.2017.7858337

DO - 10.1109/ASPDAC.2017.7858337

M3 - Conference contribution

AN - SCOPUS:85015266925

T3 - Proceedings of the Asia and South Pacific Design Automation Conference, ASP-DAC

SP - 295

EP - 298

BT - 2017 22nd Asia and South Pacific Design Automation Conference, ASP-DAC 2017

PB - Institute of Electrical and Electronics Engineers Inc.

ER -

Wu CY, Cheng CH, Ou-Yang YH, Chen CC, Chen WM, Ker MD et al. Design considerations and clinical applications of closed-loop neural disorder control SoCs. In 2017 22nd Asia and South Pacific Design Automation Conference, ASP-DAC 2017. Institute of Electrical and Electronics Engineers Inc. 2017. p. 295-298. 7858337. (Proceedings of the Asia and South Pacific Design Automation Conference, ASP-DAC). https://doi.org/10.1109/ASPDAC.2017.7858337