Dynamic ultrasound with a novel technique for clinical assessment of the Subacromial Space Stenosis

A Pilot study

Yu Lin Tsai, Yuh Ping Tsai, Meng Fen Tsai, Fong-chin Su

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Subacromial space is the margin between the humeral head and the acromion. People with subacromial space stenosis (SSS) caused by narrowing of the acromiohumeral distance (AHD) are predisposed to impingement syndrome or rotator cuff disease (RCD). Ultrasound (US) enables physicians or radiologists to dynamically assess AHD in different shoulder joint positions and has been well studied. However, a few studies have discussed and quantified the severity of SSS with the ratio of AHD displacement and the slope of AHD decease. The present study aims to investigate the dynamic change of AHD using a tracking algorithm optimized for tracking bone movement, and evaluate the test-retest reliability in healthy volunteers. Volunteers without history of recent trauma, shoulder fractures, shoulder instability, shoulder surgery or clinical treatment for a shoulder injury were recruited in this study. Dynamic US AHD measurement was performed by an experienced physician on all participants bilaterally using three views of B-mode image in passive movement of upper arm (from neutral position to 45 degrees abduction). The dynamic images were divided into frames and tracked with NIH software by another two observers without any information of subjects. (1) Maximal AHD; (2) minimal AHD; (3) the slope of linear function of AHD decrease were then analyzed to determine the intraclass correlation coefficient (ICC) for inter- and intra-observer reliability. 16 AHD measurements were performed on bilateral shoulders in 8 college volunteers (6 males, 2 females, age: 25 ± 1.3 years). Except the minimal AHD, most parameters demonstrated high ICC value (0.82 – 0.93) meaning good to excellent agreement for both inter- and intra-observer comparisons. Dynamic US with tracking technique could provide an appropriate quantitative measurement for AHD and give more clinical information in shoulder impingement or rotator cuff disease.

Original languageEnglish
Title of host publication6th European Conference of the International Federation for Medical and Biological Engineering - MBEC 2014
PublisherSpringer Verlag
Pages236-239
Number of pages4
Volume45
ISBN (Electronic)9783319111278
DOIs
Publication statusPublished - 2015
Event6th European Conference of the International Federation for Medical and Biological Engineering, MBEC 2014 - Dubrovnik, Croatia
Duration: 2014 Sep 72014 Sep 11

Other

Other6th European Conference of the International Federation for Medical and Biological Engineering, MBEC 2014
CountryCroatia
CityDubrovnik
Period14-09-0714-09-11

Fingerprint

Ultrasonics
Distance measurement
Surgery
Bone

All Science Journal Classification (ASJC) codes

  • Biomedical Engineering
  • Bioengineering

Cite this

Tsai, Y. L., Tsai, Y. P., Tsai, M. F., & Su, F. (2015). Dynamic ultrasound with a novel technique for clinical assessment of the Subacromial Space Stenosis: A Pilot study. In 6th European Conference of the International Federation for Medical and Biological Engineering - MBEC 2014 (Vol. 45, pp. 236-239). Springer Verlag. https://doi.org/10.1007/978-3-319-11128-5_59
Tsai, Yu Lin ; Tsai, Yuh Ping ; Tsai, Meng Fen ; Su, Fong-chin. / Dynamic ultrasound with a novel technique for clinical assessment of the Subacromial Space Stenosis : A Pilot study. 6th European Conference of the International Federation for Medical and Biological Engineering - MBEC 2014. Vol. 45 Springer Verlag, 2015. pp. 236-239
@inproceedings{e05e019b9bb04fe8808199bdd020a15f,
title = "Dynamic ultrasound with a novel technique for clinical assessment of the Subacromial Space Stenosis: A Pilot study",
abstract = "Subacromial space is the margin between the humeral head and the acromion. People with subacromial space stenosis (SSS) caused by narrowing of the acromiohumeral distance (AHD) are predisposed to impingement syndrome or rotator cuff disease (RCD). Ultrasound (US) enables physicians or radiologists to dynamically assess AHD in different shoulder joint positions and has been well studied. However, a few studies have discussed and quantified the severity of SSS with the ratio of AHD displacement and the slope of AHD decease. The present study aims to investigate the dynamic change of AHD using a tracking algorithm optimized for tracking bone movement, and evaluate the test-retest reliability in healthy volunteers. Volunteers without history of recent trauma, shoulder fractures, shoulder instability, shoulder surgery or clinical treatment for a shoulder injury were recruited in this study. Dynamic US AHD measurement was performed by an experienced physician on all participants bilaterally using three views of B-mode image in passive movement of upper arm (from neutral position to 45 degrees abduction). The dynamic images were divided into frames and tracked with NIH software by another two observers without any information of subjects. (1) Maximal AHD; (2) minimal AHD; (3) the slope of linear function of AHD decrease were then analyzed to determine the intraclass correlation coefficient (ICC) for inter- and intra-observer reliability. 16 AHD measurements were performed on bilateral shoulders in 8 college volunteers (6 males, 2 females, age: 25 ± 1.3 years). Except the minimal AHD, most parameters demonstrated high ICC value (0.82 – 0.93) meaning good to excellent agreement for both inter- and intra-observer comparisons. Dynamic US with tracking technique could provide an appropriate quantitative measurement for AHD and give more clinical information in shoulder impingement or rotator cuff disease.",
author = "Tsai, {Yu Lin} and Tsai, {Yuh Ping} and Tsai, {Meng Fen} and Fong-chin Su",
year = "2015",
doi = "10.1007/978-3-319-11128-5_59",
language = "English",
volume = "45",
pages = "236--239",
booktitle = "6th European Conference of the International Federation for Medical and Biological Engineering - MBEC 2014",
publisher = "Springer Verlag",
address = "Germany",

}

Tsai, YL, Tsai, YP, Tsai, MF & Su, F 2015, Dynamic ultrasound with a novel technique for clinical assessment of the Subacromial Space Stenosis: A Pilot study. in 6th European Conference of the International Federation for Medical and Biological Engineering - MBEC 2014. vol. 45, Springer Verlag, pp. 236-239, 6th European Conference of the International Federation for Medical and Biological Engineering, MBEC 2014, Dubrovnik, Croatia, 14-09-07. https://doi.org/10.1007/978-3-319-11128-5_59

Dynamic ultrasound with a novel technique for clinical assessment of the Subacromial Space Stenosis : A Pilot study. / Tsai, Yu Lin; Tsai, Yuh Ping; Tsai, Meng Fen; Su, Fong-chin.

6th European Conference of the International Federation for Medical and Biological Engineering - MBEC 2014. Vol. 45 Springer Verlag, 2015. p. 236-239.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - Dynamic ultrasound with a novel technique for clinical assessment of the Subacromial Space Stenosis

T2 - A Pilot study

AU - Tsai, Yu Lin

AU - Tsai, Yuh Ping

AU - Tsai, Meng Fen

AU - Su, Fong-chin

PY - 2015

Y1 - 2015

N2 - Subacromial space is the margin between the humeral head and the acromion. People with subacromial space stenosis (SSS) caused by narrowing of the acromiohumeral distance (AHD) are predisposed to impingement syndrome or rotator cuff disease (RCD). Ultrasound (US) enables physicians or radiologists to dynamically assess AHD in different shoulder joint positions and has been well studied. However, a few studies have discussed and quantified the severity of SSS with the ratio of AHD displacement and the slope of AHD decease. The present study aims to investigate the dynamic change of AHD using a tracking algorithm optimized for tracking bone movement, and evaluate the test-retest reliability in healthy volunteers. Volunteers without history of recent trauma, shoulder fractures, shoulder instability, shoulder surgery or clinical treatment for a shoulder injury were recruited in this study. Dynamic US AHD measurement was performed by an experienced physician on all participants bilaterally using three views of B-mode image in passive movement of upper arm (from neutral position to 45 degrees abduction). The dynamic images were divided into frames and tracked with NIH software by another two observers without any information of subjects. (1) Maximal AHD; (2) minimal AHD; (3) the slope of linear function of AHD decrease were then analyzed to determine the intraclass correlation coefficient (ICC) for inter- and intra-observer reliability. 16 AHD measurements were performed on bilateral shoulders in 8 college volunteers (6 males, 2 females, age: 25 ± 1.3 years). Except the minimal AHD, most parameters demonstrated high ICC value (0.82 – 0.93) meaning good to excellent agreement for both inter- and intra-observer comparisons. Dynamic US with tracking technique could provide an appropriate quantitative measurement for AHD and give more clinical information in shoulder impingement or rotator cuff disease.

AB - Subacromial space is the margin between the humeral head and the acromion. People with subacromial space stenosis (SSS) caused by narrowing of the acromiohumeral distance (AHD) are predisposed to impingement syndrome or rotator cuff disease (RCD). Ultrasound (US) enables physicians or radiologists to dynamically assess AHD in different shoulder joint positions and has been well studied. However, a few studies have discussed and quantified the severity of SSS with the ratio of AHD displacement and the slope of AHD decease. The present study aims to investigate the dynamic change of AHD using a tracking algorithm optimized for tracking bone movement, and evaluate the test-retest reliability in healthy volunteers. Volunteers without history of recent trauma, shoulder fractures, shoulder instability, shoulder surgery or clinical treatment for a shoulder injury were recruited in this study. Dynamic US AHD measurement was performed by an experienced physician on all participants bilaterally using three views of B-mode image in passive movement of upper arm (from neutral position to 45 degrees abduction). The dynamic images were divided into frames and tracked with NIH software by another two observers without any information of subjects. (1) Maximal AHD; (2) minimal AHD; (3) the slope of linear function of AHD decrease were then analyzed to determine the intraclass correlation coefficient (ICC) for inter- and intra-observer reliability. 16 AHD measurements were performed on bilateral shoulders in 8 college volunteers (6 males, 2 females, age: 25 ± 1.3 years). Except the minimal AHD, most parameters demonstrated high ICC value (0.82 – 0.93) meaning good to excellent agreement for both inter- and intra-observer comparisons. Dynamic US with tracking technique could provide an appropriate quantitative measurement for AHD and give more clinical information in shoulder impingement or rotator cuff disease.

UR - http://www.scopus.com/inward/record.url?scp=84937780484&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84937780484&partnerID=8YFLogxK

U2 - 10.1007/978-3-319-11128-5_59

DO - 10.1007/978-3-319-11128-5_59

M3 - Conference contribution

VL - 45

SP - 236

EP - 239

BT - 6th European Conference of the International Federation for Medical and Biological Engineering - MBEC 2014

PB - Springer Verlag

ER -

Tsai YL, Tsai YP, Tsai MF, Su F. Dynamic ultrasound with a novel technique for clinical assessment of the Subacromial Space Stenosis: A Pilot study. In 6th European Conference of the International Federation for Medical and Biological Engineering - MBEC 2014. Vol. 45. Springer Verlag. 2015. p. 236-239 https://doi.org/10.1007/978-3-319-11128-5_59