Abstract
In this study, by integrating a power factor correction buck-boost cell with a dc/dc flyback cell and adding an auxiliary transformer for energy-divider approach, a single-stage high-power factor correction (HPFC) ac/dc flyback converter with lowvoltage stress is proposed. The proposed converter exhibits the capabilities of high-power factor and low-voltage stress across the bulk capacitor when its dc/dc cell operates in continuous conduction mode. In this study, the operating principle is presented. The small-signal model of the proposed converter is also derived herein. It shows that the proposed converter with an auxiliary transformer exhibits better dynamical behaviour than the single-stage HPFC ac/dc flyback converter without an auxiliary transformer. Moreover, a proportional-integral controller is well designed for output voltage regulation. Finally, the accuracy of theoretical analysis and performances of overall system are thereby validated by experimental results.
| Original language | English |
|---|---|
| Pages (from-to) | 1624-1633 |
| Number of pages | 10 |
| Journal | IET Power Electronics |
| Volume | 5 |
| Issue number | 9 |
| DOIs | |
| Publication status | Published - 2012 |
All Science Journal Classification (ASJC) codes
- Electrical and Electronic Engineering