TY - JOUR
T1 - Effect of core suture technique and type on the gliding resistance during cyclic motion following flexor tendon repair
T2 - A cadaveric study
AU - Moriya, Tamami
AU - Zhao, Chunfeng
AU - Yamashita, Toshihiko
AU - An, Kai Nan
AU - Amadio, Peter C.
N1 - Publisher Copyright:
© 2010 Orthopaedic Research Society.
PY - 2010
Y1 - 2010
N2 - We investigated the effects of two suture techniques using three suture types in a human model in vitro.We obtained 60 flexor digitorum profundus (FDP) tendons from cadavers and measured the gliding resistance during 1,000 cycles of simulated flexion-extension motion and load to failure of six groups: the modified Kessler (MK) repair using 3-0 coated, braided polyester (Ethibond, Ethicon, Somerville, NJ), 3-0 coated, braided polyester/monofilament polyethylene composite (FiberWire®; Arthrex, Naples, FL), or 4-0 FiberWire; and the Massachusetts General Hospital (MGH) repair using 3-0 Ethibond, 3-0 FiberWire, or 4-0 FiberWire. The 3-0 Ethibond MGH suture had significantly higher ultimate load to failure than the 3-0 or 4-0 FiberWire MK suture. The 3-0 and 4-0 FiberWire MGH sutures had significantly higher load to failure than the three MK groups. The gliding resistances of the three MGH groups were significantly higher than that of the three corresponding MK groups. The MGH repair had more gliding resistance than an MK repair, even when comparing large diameter suture in the MK repair with smaller diameter suture in the MGH repair. In this study, suture technique was more important in predicting repair load to failure and gliding resistance than the nature or caliber of the suture material that was used.
AB - We investigated the effects of two suture techniques using three suture types in a human model in vitro.We obtained 60 flexor digitorum profundus (FDP) tendons from cadavers and measured the gliding resistance during 1,000 cycles of simulated flexion-extension motion and load to failure of six groups: the modified Kessler (MK) repair using 3-0 coated, braided polyester (Ethibond, Ethicon, Somerville, NJ), 3-0 coated, braided polyester/monofilament polyethylene composite (FiberWire®; Arthrex, Naples, FL), or 4-0 FiberWire; and the Massachusetts General Hospital (MGH) repair using 3-0 Ethibond, 3-0 FiberWire, or 4-0 FiberWire. The 3-0 Ethibond MGH suture had significantly higher ultimate load to failure than the 3-0 or 4-0 FiberWire MK suture. The 3-0 and 4-0 FiberWire MGH sutures had significantly higher load to failure than the three MK groups. The gliding resistances of the three MGH groups were significantly higher than that of the three corresponding MK groups. The MGH repair had more gliding resistance than an MK repair, even when comparing large diameter suture in the MK repair with smaller diameter suture in the MGH repair. In this study, suture technique was more important in predicting repair load to failure and gliding resistance than the nature or caliber of the suture material that was used.
UR - http://www.scopus.com/inward/record.url?scp=77957969752&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77957969752&partnerID=8YFLogxK
U2 - 10.1002/jor.21177
DO - 10.1002/jor.21177
M3 - Article
C2 - 20872584
AN - SCOPUS:77957969752
SN - 0736-0266
VL - 28
SP - 1475
EP - 1481
JO - Journal of Orthopaedic Research
JF - Journal of Orthopaedic Research
IS - 11
ER -