Effect of finite electrode area ratio on high-frequency Langmuir probe measurements

M. Shimoyama, Oyama Koichiro, T. Abe, A. W. Yau

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Langmuir probe (LP) measurement generally requires a reference electrode with large surface area compared with that of a probe. Whereas a reference electrode with large surface area is available in laboratory experiments, surface area of the reference electrode is limited when the probe is installed on a small spacecraft such as a sounding rocket. Insufficient electrode area ratio of the reference electrode to the probe leads to distortion of the currentvoltage (IV) characteristics and therefore the derived electron temperature and density might be erroneous. In order to investigate the effect of finite electrode area ratio on LP measurements, we have carried out a laboratory simulation by setting up a model sounding rocket with whole apparatus for LP measurement in a vacuum chamber. By changing the frequency of sweep voltage applied to the probe from 0.1Hz to 3kHz, we have derived an equivalent resistance and capacitance of the reference electrode sheath, which was thought to be the principal cause of distortion in IV characteristics. The result shows that when the electrode area ratio is 124, the electron temperature is unaffected by the impedance of the reference electrode while the electron density is underestimated by 50%. In addition, the high sweep frequency method introduced here turned out to be an effective approach to make measurements with LP possible even when a sufficient surface area ratio cannot be achieved.

Original languageEnglish
Article number075205
JournalJournal of Physics D: Applied Physics
Volume45
Issue number7
DOIs
Publication statusPublished - 2012 Feb 22

Fingerprint

Langmuir probes
electrostatic probes
Electrodes
electrodes
Sounding rockets
sounding rockets
probes
Electron temperature
Carrier concentration
electron energy
sweep frequency
vacuum chambers
sheaths
Spacecraft
spacecraft
Capacitance
capacitance
impedance
Vacuum

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics
  • Acoustics and Ultrasonics
  • Surfaces, Coatings and Films

Cite this

@article{5f9f0d86e3cf4797a8b37205ddee7e95,
title = "Effect of finite electrode area ratio on high-frequency Langmuir probe measurements",
abstract = "Langmuir probe (LP) measurement generally requires a reference electrode with large surface area compared with that of a probe. Whereas a reference electrode with large surface area is available in laboratory experiments, surface area of the reference electrode is limited when the probe is installed on a small spacecraft such as a sounding rocket. Insufficient electrode area ratio of the reference electrode to the probe leads to distortion of the currentvoltage (IV) characteristics and therefore the derived electron temperature and density might be erroneous. In order to investigate the effect of finite electrode area ratio on LP measurements, we have carried out a laboratory simulation by setting up a model sounding rocket with whole apparatus for LP measurement in a vacuum chamber. By changing the frequency of sweep voltage applied to the probe from 0.1Hz to 3kHz, we have derived an equivalent resistance and capacitance of the reference electrode sheath, which was thought to be the principal cause of distortion in IV characteristics. The result shows that when the electrode area ratio is 124, the electron temperature is unaffected by the impedance of the reference electrode while the electron density is underestimated by 50{\%}. In addition, the high sweep frequency method introduced here turned out to be an effective approach to make measurements with LP possible even when a sufficient surface area ratio cannot be achieved.",
author = "M. Shimoyama and Oyama Koichiro and T. Abe and Yau, {A. W.}",
year = "2012",
month = "2",
day = "22",
doi = "10.1088/0022-3727/45/7/075205",
language = "English",
volume = "45",
journal = "Journal Physics D: Applied Physics",
issn = "0022-3727",
publisher = "IOP Publishing Ltd.",
number = "7",

}

Effect of finite electrode area ratio on high-frequency Langmuir probe measurements. / Shimoyama, M.; Koichiro, Oyama; Abe, T.; Yau, A. W.

In: Journal of Physics D: Applied Physics, Vol. 45, No. 7, 075205, 22.02.2012.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Effect of finite electrode area ratio on high-frequency Langmuir probe measurements

AU - Shimoyama, M.

AU - Koichiro, Oyama

AU - Abe, T.

AU - Yau, A. W.

PY - 2012/2/22

Y1 - 2012/2/22

N2 - Langmuir probe (LP) measurement generally requires a reference electrode with large surface area compared with that of a probe. Whereas a reference electrode with large surface area is available in laboratory experiments, surface area of the reference electrode is limited when the probe is installed on a small spacecraft such as a sounding rocket. Insufficient electrode area ratio of the reference electrode to the probe leads to distortion of the currentvoltage (IV) characteristics and therefore the derived electron temperature and density might be erroneous. In order to investigate the effect of finite electrode area ratio on LP measurements, we have carried out a laboratory simulation by setting up a model sounding rocket with whole apparatus for LP measurement in a vacuum chamber. By changing the frequency of sweep voltage applied to the probe from 0.1Hz to 3kHz, we have derived an equivalent resistance and capacitance of the reference electrode sheath, which was thought to be the principal cause of distortion in IV characteristics. The result shows that when the electrode area ratio is 124, the electron temperature is unaffected by the impedance of the reference electrode while the electron density is underestimated by 50%. In addition, the high sweep frequency method introduced here turned out to be an effective approach to make measurements with LP possible even when a sufficient surface area ratio cannot be achieved.

AB - Langmuir probe (LP) measurement generally requires a reference electrode with large surface area compared with that of a probe. Whereas a reference electrode with large surface area is available in laboratory experiments, surface area of the reference electrode is limited when the probe is installed on a small spacecraft such as a sounding rocket. Insufficient electrode area ratio of the reference electrode to the probe leads to distortion of the currentvoltage (IV) characteristics and therefore the derived electron temperature and density might be erroneous. In order to investigate the effect of finite electrode area ratio on LP measurements, we have carried out a laboratory simulation by setting up a model sounding rocket with whole apparatus for LP measurement in a vacuum chamber. By changing the frequency of sweep voltage applied to the probe from 0.1Hz to 3kHz, we have derived an equivalent resistance and capacitance of the reference electrode sheath, which was thought to be the principal cause of distortion in IV characteristics. The result shows that when the electrode area ratio is 124, the electron temperature is unaffected by the impedance of the reference electrode while the electron density is underestimated by 50%. In addition, the high sweep frequency method introduced here turned out to be an effective approach to make measurements with LP possible even when a sufficient surface area ratio cannot be achieved.

UR - http://www.scopus.com/inward/record.url?scp=84863407076&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84863407076&partnerID=8YFLogxK

U2 - 10.1088/0022-3727/45/7/075205

DO - 10.1088/0022-3727/45/7/075205

M3 - Article

AN - SCOPUS:84863407076

VL - 45

JO - Journal Physics D: Applied Physics

JF - Journal Physics D: Applied Physics

SN - 0022-3727

IS - 7

M1 - 075205

ER -