TY - GEN
T1 - Energy-saving techniques of full-scale green building analysis research - Taiwan's first zero-carbon green building
AU - Wang, Yu Chung
AU - Lin, Hsien Te
PY - 2012
Y1 - 2012
N2 - This research is based on Taiwan's first zero-carbon green building-Magic School of Green Technology in National Cheng Kung University. Actual energy consumption will be measured to explore benefits of energy-saving. The design origin for this building encompasses 13 green energy-saving techniques. United States Department of Energy dynamic building energy analytical software, eQUEST, is used to execute the strictest energy consumption analytical assessment. It is forecasted to reach an energy-saving efficiency of 65% with energy use intensity (EUI) of 43 kWh/m2.yr for the whole building, far below that of 169 kWh/m2.yr found in Taiwan low/mid-rise office buildings. This building has begun operation in 2011, through actual readings from Building Energy Management System (BEMS) during January to June, first-half-year accumulated EUI of 19.3 kWh/m2.yr against eQUEST analytical assessment of 22.5 kWh/m2.yr for the same period. Actual energy consumption analysis for air conditioning, lighting, socket outlet, and power equipment, respectively recorded 41.7%, 11%, 22.3%, and 25% in June. Demonstrating that eQUEST analytical assessed value is very consistent with building's actual energy consumption readings. The energy consumption standard in the experimental research behind the Magic School of Green Technology stands at world class.
AB - This research is based on Taiwan's first zero-carbon green building-Magic School of Green Technology in National Cheng Kung University. Actual energy consumption will be measured to explore benefits of energy-saving. The design origin for this building encompasses 13 green energy-saving techniques. United States Department of Energy dynamic building energy analytical software, eQUEST, is used to execute the strictest energy consumption analytical assessment. It is forecasted to reach an energy-saving efficiency of 65% with energy use intensity (EUI) of 43 kWh/m2.yr for the whole building, far below that of 169 kWh/m2.yr found in Taiwan low/mid-rise office buildings. This building has begun operation in 2011, through actual readings from Building Energy Management System (BEMS) during January to June, first-half-year accumulated EUI of 19.3 kWh/m2.yr against eQUEST analytical assessment of 22.5 kWh/m2.yr for the same period. Actual energy consumption analysis for air conditioning, lighting, socket outlet, and power equipment, respectively recorded 41.7%, 11%, 22.3%, and 25% in June. Demonstrating that eQUEST analytical assessed value is very consistent with building's actual energy consumption readings. The energy consumption standard in the experimental research behind the Magic School of Green Technology stands at world class.
UR - http://www.scopus.com/inward/record.url?scp=81255207938&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=81255207938&partnerID=8YFLogxK
U2 - 10.4028/www.scientific.net/AMM.121-126.3058
DO - 10.4028/www.scientific.net/AMM.121-126.3058
M3 - Conference contribution
AN - SCOPUS:81255207938
SN - 9783037852828
T3 - Applied Mechanics and Materials
SP - 3058
EP - 3066
BT - Frontiers of Manufacturing and Design Science II
PB - Trans Tech Publications Ltd
T2 - 2nd International Conference on Frontiers of Manufacturing and Design Science, ICFMD 2011
Y2 - 11 December 2011 through 13 December 2011
ER -