Abstract

As wind power retains a significant proportion of generation mix in the electric system, we foresee that less fossil fuel units will be on service. Under this situation, it may impact system's frequency security due to the lack of frequency support from units. To make up for such a system change, wind turbines should actively provide frequency response upon request. For wind turbines to achieve this goal, active power output of the wind turbine should be controllable so that the generating margin could be preserved for frequency response. Therefore, the presentation of this paper will begin with the demonstration of the control scheme for the doubly fed induction generator (DFIG). Simulation results validate the effectiveness of the methodology in regulating wind power upon operator's request, while stability is assured under variant wind speeds. Following that, this paper will explore several operating strategies for DFIGs to support system frequency with less sacrifice in the wind energy production. Simulation results show that the proposed strategies can enhance regulation performance in the high wind penetrated power system.

Original languageEnglish
Article number5512564
Pages (from-to)710-718
Number of pages9
JournalIEEE Transactions on Power Systems
Volume26
Issue number2
DOIs
Publication statusPublished - 2011 May 1

Fingerprint

Wind power
Frequency response
Wind turbines
Asynchronous generators
Fossil fuels
Demonstrations

All Science Journal Classification (ASJC) codes

  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering

Cite this

@article{1f87a88e3bb3414581fc76874cbb02f2,
title = "Enhancing frequency response control by DFIGs in the high wind penetrated power systems",
abstract = "As wind power retains a significant proportion of generation mix in the electric system, we foresee that less fossil fuel units will be on service. Under this situation, it may impact system's frequency security due to the lack of frequency support from units. To make up for such a system change, wind turbines should actively provide frequency response upon request. For wind turbines to achieve this goal, active power output of the wind turbine should be controllable so that the generating margin could be preserved for frequency response. Therefore, the presentation of this paper will begin with the demonstration of the control scheme for the doubly fed induction generator (DFIG). Simulation results validate the effectiveness of the methodology in regulating wind power upon operator's request, while stability is assured under variant wind speeds. Following that, this paper will explore several operating strategies for DFIGs to support system frequency with less sacrifice in the wind energy production. Simulation results show that the proposed strategies can enhance regulation performance in the high wind penetrated power system.",
author = "Le-Ren Chang-Chien and Lin, {Wei Ting} and Yin, {Yao Ching}",
year = "2011",
month = "5",
day = "1",
doi = "10.1109/TPWRS.2010.2052402",
language = "English",
volume = "26",
pages = "710--718",
journal = "IEEE Transactions on Power Systems",
issn = "0885-8950",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "2",

}

Enhancing frequency response control by DFIGs in the high wind penetrated power systems. / Chang-Chien, Le-Ren; Lin, Wei Ting; Yin, Yao Ching.

In: IEEE Transactions on Power Systems, Vol. 26, No. 2, 5512564, 01.05.2011, p. 710-718.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Enhancing frequency response control by DFIGs in the high wind penetrated power systems

AU - Chang-Chien, Le-Ren

AU - Lin, Wei Ting

AU - Yin, Yao Ching

PY - 2011/5/1

Y1 - 2011/5/1

N2 - As wind power retains a significant proportion of generation mix in the electric system, we foresee that less fossil fuel units will be on service. Under this situation, it may impact system's frequency security due to the lack of frequency support from units. To make up for such a system change, wind turbines should actively provide frequency response upon request. For wind turbines to achieve this goal, active power output of the wind turbine should be controllable so that the generating margin could be preserved for frequency response. Therefore, the presentation of this paper will begin with the demonstration of the control scheme for the doubly fed induction generator (DFIG). Simulation results validate the effectiveness of the methodology in regulating wind power upon operator's request, while stability is assured under variant wind speeds. Following that, this paper will explore several operating strategies for DFIGs to support system frequency with less sacrifice in the wind energy production. Simulation results show that the proposed strategies can enhance regulation performance in the high wind penetrated power system.

AB - As wind power retains a significant proportion of generation mix in the electric system, we foresee that less fossil fuel units will be on service. Under this situation, it may impact system's frequency security due to the lack of frequency support from units. To make up for such a system change, wind turbines should actively provide frequency response upon request. For wind turbines to achieve this goal, active power output of the wind turbine should be controllable so that the generating margin could be preserved for frequency response. Therefore, the presentation of this paper will begin with the demonstration of the control scheme for the doubly fed induction generator (DFIG). Simulation results validate the effectiveness of the methodology in regulating wind power upon operator's request, while stability is assured under variant wind speeds. Following that, this paper will explore several operating strategies for DFIGs to support system frequency with less sacrifice in the wind energy production. Simulation results show that the proposed strategies can enhance regulation performance in the high wind penetrated power system.

UR - http://www.scopus.com/inward/record.url?scp=79955541414&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79955541414&partnerID=8YFLogxK

U2 - 10.1109/TPWRS.2010.2052402

DO - 10.1109/TPWRS.2010.2052402

M3 - Article

AN - SCOPUS:79955541414

VL - 26

SP - 710

EP - 718

JO - IEEE Transactions on Power Systems

JF - IEEE Transactions on Power Systems

SN - 0885-8950

IS - 2

M1 - 5512564

ER -