TY - GEN
T1 - Establish sorptive test system and validation of the reduction indoor HCHO concentrations by building material in Taiwan
AU - Chiang, Che Ming
AU - Huang, Kun Chih
AU - Lee, Ching Chang
AU - Chen, Cheng Chen
N1 - Copyright:
Copyright 2011 Elsevier B.V., All rights reserved.
PY - 2011
Y1 - 2011
N2 - With the countries in the world gradually emphasize that the well-controlled of indoor air quality (IAQ) and indoor environment health (IEH) would reduce the hazards of human health. This study response the international community has been launched sorptive building materials, such as standards ISO, JIS, etc in recent years, and based on ISO 16000-23 through the small-scale chamber equipment system to develop and establish "sorptive building material test system, SBMTS", National Performance Laboratory Center in Taiwan. In accordance with standard operating procedures (SOP) to validation of the test system and provided for sorption test by three building materials. The results was verified SBMTS to conform concentrations of HCHO recovery more than 80% by repeatedly sampling and the system was meet the stability through the instrument monitoring display, which could to provide the relevant performance validation and testing for SBM. This study according results with sorption test of select foreign and domestic by building materials, and the performance calculation include the sorption flux, Fm and the equivalent ventilation rate, Fv, eq by SBM, which could provide to reference of the national standards.
AB - With the countries in the world gradually emphasize that the well-controlled of indoor air quality (IAQ) and indoor environment health (IEH) would reduce the hazards of human health. This study response the international community has been launched sorptive building materials, such as standards ISO, JIS, etc in recent years, and based on ISO 16000-23 through the small-scale chamber equipment system to develop and establish "sorptive building material test system, SBMTS", National Performance Laboratory Center in Taiwan. In accordance with standard operating procedures (SOP) to validation of the test system and provided for sorption test by three building materials. The results was verified SBMTS to conform concentrations of HCHO recovery more than 80% by repeatedly sampling and the system was meet the stability through the instrument monitoring display, which could to provide the relevant performance validation and testing for SBM. This study according results with sorption test of select foreign and domestic by building materials, and the performance calculation include the sorption flux, Fm and the equivalent ventilation rate, Fv, eq by SBM, which could provide to reference of the national standards.
UR - http://www.scopus.com/inward/record.url?scp=80052998012&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=80052998012&partnerID=8YFLogxK
U2 - 10.4028/www.scientific.net/AMR.314-316.1435
DO - 10.4028/www.scientific.net/AMR.314-316.1435
M3 - Conference contribution
AN - SCOPUS:80052998012
SN - 9783037852156
T3 - Advanced Materials Research
SP - 1435
EP - 1438
BT - Advanced Manufacturing Technology
T2 - 2011 International Conference on Advanced Design and Manufacturing Engineering, ADME 2011
Y2 - 16 September 2011 through 18 September 2011
ER -