Abstract
A study was performed to demonstrate that magnetization measurement is a fast, sensitive, and nondestructive way to determine the average size and amount of iron nanoparticles in HiPco NTs. Furthermore, it was found that Ms for the iron nanoparticles with ∼3 nm mean size in HiPco NTs is about half of that bulk iron.
| Original language | English |
|---|---|
| Pages (from-to) | 4601-4603 |
| Number of pages | 3 |
| Journal | Applied Physics Letters |
| Volume | 83 |
| Issue number | 22 |
| DOIs | |
| Publication status | Published - 2003 Dec 1 |
All Science Journal Classification (ASJC) codes
- Physics and Astronomy (miscellaneous)