TY - JOUR
T1 - Feasibility of using a video-based motion analysis system for measuring thumb kinematics
AU - Kuo, Li Chieh
AU - Su, Fong Chin
AU - Chiu, Haw Yen
AU - Yu, Chin Yin
N1 - Funding Information:
This work was supported by National Science Council grant NSC89-22218-E-006–066 and NSC89-2314-B-006–082, Taiwan. Thanks go to Lu C.D. for the assistance in using the video-fluoroscopy system.
PY - 2002/11/1
Y1 - 2002/11/1
N2 - While several different methods have been used to measure hand kinematics, fluoroscopy is generally considered to be the most accurate. Recently, video-based motion analysis has been developed for the measurement of joint kinematics. This method is versatile, easy to use, and can measure motions dynamically. Surface markers are most commonly used in the video-based motion systems. However, whether the surface markers placed on the thumb accurately represent the true kinematics of the underlying bony segment is questionable. In this study, the feasibility of surface markers to represent thumb kinematics was investigated by fluoroscopy. Both the positions of surface markers and bony landmarks were simultaneous recorded and then digitized. The Ra2 values comparing the angular changes of the thumb interphalangeal, metacarpal and carpometacarpal joints derived using the surface markers or bony landmarks were 0.9986, 0.9730 and 0.9186 in the flexion/extension plane respectively, 0.8837, 0.9697 and 0.8775 in the abduction/adduction plane; and 0.9884, 0.9643 and 0.9431 in the opposition plane. The ranges, mean and standard deviation of the absolute differences between calculated angles of different marker sets were also compared. These data revealed that the similarities of the two different marker techniques throughout the motion cycle were high. The differences between the two methods were also within clinically allowable range of ±5°. It is concluded that the application of the video-based motion analysis system with surface markers to thumb kinematics is warranted.
AB - While several different methods have been used to measure hand kinematics, fluoroscopy is generally considered to be the most accurate. Recently, video-based motion analysis has been developed for the measurement of joint kinematics. This method is versatile, easy to use, and can measure motions dynamically. Surface markers are most commonly used in the video-based motion systems. However, whether the surface markers placed on the thumb accurately represent the true kinematics of the underlying bony segment is questionable. In this study, the feasibility of surface markers to represent thumb kinematics was investigated by fluoroscopy. Both the positions of surface markers and bony landmarks were simultaneous recorded and then digitized. The Ra2 values comparing the angular changes of the thumb interphalangeal, metacarpal and carpometacarpal joints derived using the surface markers or bony landmarks were 0.9986, 0.9730 and 0.9186 in the flexion/extension plane respectively, 0.8837, 0.9697 and 0.8775 in the abduction/adduction plane; and 0.9884, 0.9643 and 0.9431 in the opposition plane. The ranges, mean and standard deviation of the absolute differences between calculated angles of different marker sets were also compared. These data revealed that the similarities of the two different marker techniques throughout the motion cycle were high. The differences between the two methods were also within clinically allowable range of ±5°. It is concluded that the application of the video-based motion analysis system with surface markers to thumb kinematics is warranted.
UR - http://www.scopus.com/inward/record.url?scp=0036843536&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0036843536&partnerID=8YFLogxK
U2 - 10.1016/S0021-9290(02)00083-0
DO - 10.1016/S0021-9290(02)00083-0
M3 - Article
C2 - 12413969
AN - SCOPUS:0036843536
SN - 0021-9290
VL - 35
SP - 1499
EP - 1506
JO - Journal of Biomechanics
JF - Journal of Biomechanics
IS - 11
ER -