TY - JOUR
T1 - Finite element analysis of miniscrew implants used for orthodontic anchorage
AU - Liu, Te Chun
AU - Chang, Chih Han
AU - Wong, Tung Yiu
AU - Liu, Jia Kuang
N1 - Funding Information:
Supported by the National Science Council, Taiwan, ROC , under grants NSC 93-2320-B-006-067 and NSC 94-2320-B-006-023 .
PY - 2012/4
Y1 - 2012/4
N2 - Introduction: The miniscrew has been developed and effectively used as orthodontic anchorage, but current studies of its usage are insufficient to provide information about the underlying mechanical mechanisms. The aim of this study was to investigate the roles of bone quality, loading conditions, screw effects, and implanted depth on the biomechanics of an orthodontic miniscrew system by using finite element analysis. Methods: A 3-dimensional model with a bone block integrated with a miniscrew was constructed to simulate various cortex thicknesses, cancellous bone densities, force magnitudes and directions, screw diameters and lengths, and implanted depths of miniscrews. Results: Both stress and displacement increased with decreasing cortex thickness, whereas cancellous bone density played a minor role in the mechanical response. These 2 indexes were linearly proportional to the force magnitude and produced the highest values when the force was perpendicular to the long axis of the miniscrew. A wider screw provided superior mechanical advantages. The exposed length of the miniscrew was the real factor affecting mechanical performance. Conclusions: The screw diameter was the dominant factor for minscrew mechanical responses. Both bone stress and screw displacement decreased with increasing screw diameter and cortex thickness, and decreasing exposed length of the screw, force magnitude, and oblique loading direction.
AB - Introduction: The miniscrew has been developed and effectively used as orthodontic anchorage, but current studies of its usage are insufficient to provide information about the underlying mechanical mechanisms. The aim of this study was to investigate the roles of bone quality, loading conditions, screw effects, and implanted depth on the biomechanics of an orthodontic miniscrew system by using finite element analysis. Methods: A 3-dimensional model with a bone block integrated with a miniscrew was constructed to simulate various cortex thicknesses, cancellous bone densities, force magnitudes and directions, screw diameters and lengths, and implanted depths of miniscrews. Results: Both stress and displacement increased with decreasing cortex thickness, whereas cancellous bone density played a minor role in the mechanical response. These 2 indexes were linearly proportional to the force magnitude and produced the highest values when the force was perpendicular to the long axis of the miniscrew. A wider screw provided superior mechanical advantages. The exposed length of the miniscrew was the real factor affecting mechanical performance. Conclusions: The screw diameter was the dominant factor for minscrew mechanical responses. Both bone stress and screw displacement decreased with increasing screw diameter and cortex thickness, and decreasing exposed length of the screw, force magnitude, and oblique loading direction.
UR - http://www.scopus.com/inward/record.url?scp=84859205369&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84859205369&partnerID=8YFLogxK
U2 - 10.1016/j.ajodo.2011.11.012
DO - 10.1016/j.ajodo.2011.11.012
M3 - Article
C2 - 22464529
AN - SCOPUS:84859205369
SN - 0889-5406
VL - 141
SP - 468
EP - 476
JO - American Journal of Orthodontics and Dentofacial Orthopedics
JF - American Journal of Orthodontics and Dentofacial Orthopedics
IS - 4
ER -