Fire behaviour and structural safety of box-structured light steel houses

Ko Jen Chen, Ming Ju Tsai, Chun Ta Tzeng, Chi Ming Lai

Research output: Contribution to journalArticlepeer-review

Abstract

A single unit with dimensions of 5.6 m × 2.5 m × 3 m (H) of box-structured light steel house was adopted to investigate the fire behaviour and structural safety. The longitudinal side of the investigated unit was restrained on an existing house, and the remainder boundary was designated as the free boundary. The ignition began on the western wood crib, one of the three wood cribs (fire source) placed evenly in the middle of the room. The results showed that the highest temperature point was located underneath the ceiling of the fire room. Only the temperature around the ceiling was quite close to standard heating curve. An identical, uniform and steady standard heating curve was difficult to achieve in this full-size experiment. The extent of fire damage of this kind of light steel structure was greatly affected by the quality of the fire-resistant decoration materials.

Original languageEnglish
Pages (from-to)19-24
Number of pages6
JournalJournal of the Institution of Engineers (India): Architectural Engineering Division
Volume92
Issue numberAPRIL
Publication statusPublished - 2011 Apr 18

All Science Journal Classification (ASJC) codes

  • Architecture

Fingerprint

Dive into the research topics of 'Fire behaviour and structural safety of box-structured light steel houses'. Together they form a unique fingerprint.