TY - GEN
T1 - Load forecasting of residential row houses blocks in Taiwan
AU - Wang, Ren Jen
AU - Lin, Hsien Te
AU - Chen, Jiann Fuh
PY - 2007
Y1 - 2007
N2 - The purpose of this paper is to probe into the energy consumption of urban in Taiwan. Through the investigation and analysis of electricity consumption data from residential city blocks, this study discusses the difference of electricity consumption in row houses while they are located in different urban block patterns. There are 59 blocks, which 1,941 houses are included in, chosen to be the samples. Among them, 599 households and 434 commercial uinits are valid samples. The average energy use intensity (EUI ) is up to 33.29kWh/(m 2.yr). Considering azimuth, the average EUI of the west-elevated house is 1.33 times than that of the north-elevated house. Electricity consumption of air conditioning (AC) in housing accounts for 15.56% of the annual. Furthermore, three prediction equations are proposed in the end. The first is designed for predicting the EUI of household town house, the others are directed against the whole block area. Basing on the confidence of 95%, the R2 is between 0.82 to 0.98.
AB - The purpose of this paper is to probe into the energy consumption of urban in Taiwan. Through the investigation and analysis of electricity consumption data from residential city blocks, this study discusses the difference of electricity consumption in row houses while they are located in different urban block patterns. There are 59 blocks, which 1,941 houses are included in, chosen to be the samples. Among them, 599 households and 434 commercial uinits are valid samples. The average energy use intensity (EUI ) is up to 33.29kWh/(m 2.yr). Considering azimuth, the average EUI of the west-elevated house is 1.33 times than that of the north-elevated house. Electricity consumption of air conditioning (AC) in housing accounts for 15.56% of the annual. Furthermore, three prediction equations are proposed in the end. The first is designed for predicting the EUI of household town house, the others are directed against the whole block area. Basing on the confidence of 95%, the R2 is between 0.82 to 0.98.
UR - http://www.scopus.com/inward/record.url?scp=54949083052&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=54949083052&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:54949083052
SN - 9780889866577
T3 - Proceedings of the 3rd IASTED Asian Conference on Power and Energy Systems, AsiaPES 2007
SP - 242
EP - 247
BT - Proceedings of the 3rd IASTED Asian Conference on Power and Energy Systems, AsiaPES 2007
T2 - 3rd IASTED Asian Conference on Power and Energy Systems, AsiaPES 2007
Y2 - 2 April 2007 through 4 April 2007
ER -