A simple, compact CW sub-THz imaging system, utilizing a 0.2 and 0.6 THz Gunn diode source is presented. A silicon beam lead diode detector and a Golay cell are used for the detection. Various results are presented, which show that the CW THz imaging modality is suitable for diverse applications, such as non-destructive testing and security. The key components of the system include the Gunn diode assembly, an optical chopper, a polyethylene lens, a detector, a lock-in amplifier, and two translation stages. The beam from the Gunn diode is focused on the sample being imaged by the polyethylene lens, the transmitted or reflected beam is measured by the detector. The energy transmitted through the sample at each point in the plane of the sample is detected. Since the system has relatively few components compared to pulsed THz imaging systems, it is less expensive and easier to design and operate, although it does not provide depth or spectral information about the sample. Since no time-delay scans take place, scanning can be done quickly compared to a time-domain system, limited by the maximum velocity of the translation stages and response of the detectors. It provides information about the macroscopic features of hidden structures within materials that are transparent to sub THz radiation, such as space shuttle insulating foam, articles of clothing, and luggage.

Original languageEnglish
Article number21
Pages (from-to)132-142
Number of pages11
JournalProceedings of SPIE - The International Society for Optical Engineering
Volume5727
DOIs
Publication statusPublished - 2005 Jul 21
EventTerahertz and Gigahertz Electronics and Photonics IV - San Jose, CA, United States
Duration: 2005 Jan 232005 Jan 25

Fingerprint

Gunn diodes
Diode
Imaging
Detectors
Imaging techniques
Detector
detectors
Polyethylene
Imaging systems
Polyethylenes
polyethylenes
Lenses
Imaging System
lenses
Lens
beam leads
clothing
electric choppers
space shuttles
Space shuttles

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics
  • Computer Science Applications
  • Applied Mathematics
  • Electrical and Electronic Engineering

Cite this

Karpowicz, Nicholas ; Zhong, Hua ; Xu, Jingzhou ; Lin, Kuang-I ; Hwang, Jenn Shyong ; Zhang, Xi Cheng. / Non-destructive sub-THz CW imaging. In: Proceedings of SPIE - The International Society for Optical Engineering. 2005 ; Vol. 5727. pp. 132-142.
@article{be513cd232d0473799e1ba8902a22529,
title = "Non-destructive sub-THz CW imaging",
abstract = "A simple, compact CW sub-THz imaging system, utilizing a 0.2 and 0.6 THz Gunn diode source is presented. A silicon beam lead diode detector and a Golay cell are used for the detection. Various results are presented, which show that the CW THz imaging modality is suitable for diverse applications, such as non-destructive testing and security. The key components of the system include the Gunn diode assembly, an optical chopper, a polyethylene lens, a detector, a lock-in amplifier, and two translation stages. The beam from the Gunn diode is focused on the sample being imaged by the polyethylene lens, the transmitted or reflected beam is measured by the detector. The energy transmitted through the sample at each point in the plane of the sample is detected. Since the system has relatively few components compared to pulsed THz imaging systems, it is less expensive and easier to design and operate, although it does not provide depth or spectral information about the sample. Since no time-delay scans take place, scanning can be done quickly compared to a time-domain system, limited by the maximum velocity of the translation stages and response of the detectors. It provides information about the macroscopic features of hidden structures within materials that are transparent to sub THz radiation, such as space shuttle insulating foam, articles of clothing, and luggage.",
author = "Nicholas Karpowicz and Hua Zhong and Jingzhou Xu and Kuang-I Lin and Hwang, {Jenn Shyong} and Zhang, {Xi Cheng}",
year = "2005",
month = "7",
day = "21",
doi = "10.1117/12.590539",
language = "English",
volume = "5727",
pages = "132--142",
journal = "Proceedings of SPIE - The International Society for Optical Engineering",
issn = "0277-786X",
publisher = "SPIE",

}

Non-destructive sub-THz CW imaging. / Karpowicz, Nicholas; Zhong, Hua; Xu, Jingzhou; Lin, Kuang-I; Hwang, Jenn Shyong; Zhang, Xi Cheng.

In: Proceedings of SPIE - The International Society for Optical Engineering, Vol. 5727, 21, 21.07.2005, p. 132-142.

Research output: Contribution to journalConference article

TY - JOUR

T1 - Non-destructive sub-THz CW imaging

AU - Karpowicz, Nicholas

AU - Zhong, Hua

AU - Xu, Jingzhou

AU - Lin, Kuang-I

AU - Hwang, Jenn Shyong

AU - Zhang, Xi Cheng

PY - 2005/7/21

Y1 - 2005/7/21

N2 - A simple, compact CW sub-THz imaging system, utilizing a 0.2 and 0.6 THz Gunn diode source is presented. A silicon beam lead diode detector and a Golay cell are used for the detection. Various results are presented, which show that the CW THz imaging modality is suitable for diverse applications, such as non-destructive testing and security. The key components of the system include the Gunn diode assembly, an optical chopper, a polyethylene lens, a detector, a lock-in amplifier, and two translation stages. The beam from the Gunn diode is focused on the sample being imaged by the polyethylene lens, the transmitted or reflected beam is measured by the detector. The energy transmitted through the sample at each point in the plane of the sample is detected. Since the system has relatively few components compared to pulsed THz imaging systems, it is less expensive and easier to design and operate, although it does not provide depth or spectral information about the sample. Since no time-delay scans take place, scanning can be done quickly compared to a time-domain system, limited by the maximum velocity of the translation stages and response of the detectors. It provides information about the macroscopic features of hidden structures within materials that are transparent to sub THz radiation, such as space shuttle insulating foam, articles of clothing, and luggage.

AB - A simple, compact CW sub-THz imaging system, utilizing a 0.2 and 0.6 THz Gunn diode source is presented. A silicon beam lead diode detector and a Golay cell are used for the detection. Various results are presented, which show that the CW THz imaging modality is suitable for diverse applications, such as non-destructive testing and security. The key components of the system include the Gunn diode assembly, an optical chopper, a polyethylene lens, a detector, a lock-in amplifier, and two translation stages. The beam from the Gunn diode is focused on the sample being imaged by the polyethylene lens, the transmitted or reflected beam is measured by the detector. The energy transmitted through the sample at each point in the plane of the sample is detected. Since the system has relatively few components compared to pulsed THz imaging systems, it is less expensive and easier to design and operate, although it does not provide depth or spectral information about the sample. Since no time-delay scans take place, scanning can be done quickly compared to a time-domain system, limited by the maximum velocity of the translation stages and response of the detectors. It provides information about the macroscopic features of hidden structures within materials that are transparent to sub THz radiation, such as space shuttle insulating foam, articles of clothing, and luggage.

UR - http://www.scopus.com/inward/record.url?scp=21844446088&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=21844446088&partnerID=8YFLogxK

U2 - 10.1117/12.590539

DO - 10.1117/12.590539

M3 - Conference article

AN - SCOPUS:21844446088

VL - 5727

SP - 132

EP - 142

JO - Proceedings of SPIE - The International Society for Optical Engineering

JF - Proceedings of SPIE - The International Society for Optical Engineering

SN - 0277-786X

M1 - 21

ER -