Abstract
An attempt is made to characterise, qualitatively and quantitatively, the major differences between H∞ and H2-optimal model matching control. Conditions under which the effectiveness of model matching in H∞-norm space is superior to that in H2-norm space are derived. According to these conditions, designers can easily decide between H∞ and H2 approaches to meet the required performance.
Original language | English |
---|---|
Pages (from-to) | 2089-2091 |
Number of pages | 3 |
Journal | Electronics Letters |
Volume | 26 |
Issue number | 25 |
DOIs | |
Publication status | Published - 1990 Jan |
All Science Journal Classification (ASJC) codes
- Electrical and Electronic Engineering