Performance assessment of Ti7.5Mo alloy for removable partial denture application

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

A head-to-head comparison was made between an in-house-developed Ti-7.5Mo alloy and commonly-used grade-2 commercially pure titanium (CP-Ti) for dental casting applications. Experimental results indicated that all impurity concentrations, densities, linear thermal expansion coefficients and solid/liquid transition temperatures of Ti-7.5Mo and CP-Ti were similar. The 7-day total release of metal ions from immersed Ti-7.5Mo was acceptably low (10 µg/cm12) with no harmful elements detected. Cytotoxicity testing indicated that Ti-7.5Mo had a cell viability of 82.5%, higher than the generally accepted value (70%). X-ray diffraction patterns indicated that Ti-7.5Mo was comprised primarily of ¡AA phase with a small amount of ¢ phase, while CP-Ti showed a monolithic ¡/¡A phase. Light and scanning electron microscopy revealed that CP-Ti had a typical plate-shaped morphology, while Ti-7.5Mo alloy was featured by its much finer acicular-shaped ¡AA crystals along with equi-axed retained ¢ grain boundaries. The castability value of Ti-7.5Mo was almost double that of CP-Ti. Both grinding and cutting tests indicated that Ti-7.5Mo had much better machinability than CP-Ti. Tensile testing indicated that Ti-7.5Mo had higher tensile strength, higher elongation and lower modulus (respectively 806 MPa, 42% and 70 GPa) than CP-Ti (respectively 571 MPa, 22% and 113 GPa). Bending data showed that Ti-7.5Mo had higher bending strength, lower modulus and much larger elastic recovery angle (respectively 1154.7 MPa, 75.8 GPa and 31.5°) than CP-Ti (respectively 919.5 MPa, 125 GPa and 2.8°). From all present data it was concluded that Ti-7.5Mo alloy would be a much better material than CP-Ti for removable partial denture application.

Original languageEnglish
Pages (from-to)2311-2318
Number of pages8
JournalMaterials Transactions
Volume60
Issue number11
DOIs
Publication statusPublished - 2019

All Science Journal Classification (ASJC) codes

  • Materials Science(all)
  • Condensed Matter Physics
  • Mechanics of Materials
  • Mechanical Engineering

Fingerprint

Dive into the research topics of 'Performance assessment of Ti7.5Mo alloy for removable partial denture application'. Together they form a unique fingerprint.

Cite this