N2 - The recently-introduced Orbitrap Fusion mass spectrometry permits various types of MS2 acquisition methods. To date, these different MS2 strategies and the optimal data interpretation approach for each have not been adequately evaluated. This study comprehensively investigated the four MS2 strategies: HCD-OT (higher-energy-collisional-dissociation with Orbitrap detection), HCD-IT (HCD with ion trap, IT), CID-IT (collision-induced-dissociation with IT) and CID-OT on Orbitrap Fusion. To achieve extensive comparison and identify the optimal data interpretation method for each technique, several search engines (SEQUEST and Mascot) and post-processing methods (score-based, PeptideProphet, and Percolator) were assessed for all techniques for the analysis of a human cell proteome. It was found that divergent conclusions could be made from the same dataset when different data interpretation approaches were used and therefore requiring a relatively fair comparison among techniques. Percolator was chosen for comparison of techniques because it performs the best among all search engines and MS2 strategies. For the analysis of human cell proteome using individual MS2 strategies, the highest number of identifications was achieved by HCD-OT, followed by HCD-IT and CID-IT. Based on these results, we concluded that a relatively fair platform for data interpretation is necessary to avoid divergent conclusions from the same dataset, and HCD-OT and HCD-IT may be preferable for protein/peptide identification using Orbitrap Fusion.
AB - The recently-introduced Orbitrap Fusion mass spectrometry permits various types of MS2 acquisition methods. To date, these different MS2 strategies and the optimal data interpretation approach for each have not been adequately evaluated. This study comprehensively investigated the four MS2 strategies: HCD-OT (higher-energy-collisional-dissociation with Orbitrap detection), HCD-IT (HCD with ion trap, IT), CID-IT (collision-induced-dissociation with IT) and CID-OT on Orbitrap Fusion. To achieve extensive comparison and identify the optimal data interpretation method for each technique, several search engines (SEQUEST and Mascot) and post-processing methods (score-based, PeptideProphet, and Percolator) were assessed for all techniques for the analysis of a human cell proteome. It was found that divergent conclusions could be made from the same dataset when different data interpretation approaches were used and therefore requiring a relatively fair comparison among techniques. Percolator was chosen for comparison of techniques because it performs the best among all search engines and MS2 strategies. For the analysis of human cell proteome using individual MS2 strategies, the highest number of identifications was achieved by HCD-OT, followed by HCD-IT and CID-IT. Based on these results, we concluded that a relatively fair platform for data interpretation is necessary to avoid divergent conclusions from the same dataset, and HCD-OT and HCD-IT may be preferable for protein/peptide identification using Orbitrap Fusion.
UR - http://www.scopus.com/inward/record.url?scp=85006240691&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85006240691&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0160160
DO - 10.1371/journal.pone.0160160
M3 - Article
C2 - 27472422
AN - SCOPUS:85006240691
SN - 1932-6203
VL - 11
JO - PloS one
JF - PloS one
IS - 7
M1 - e0160160
ER -