Rapid microfluidic paper-based platform for low concentration formaldehyde detection

John Mello Camille C. Guzman, Lemmuel L. Tayo, Chan Chiung Liu, Yao Nan Wang, Lung Ming Fu

Research output: Contribution to journalArticle

19 Citations (Scopus)

Abstract

An integrated platform consisting of a microfluidic paper-based analytical device (μPAD) and a portable detection system is proposed for low concentration formaldehyde (CH2O) detection. In the proposed approach, the reaction zone of the μPAD is coated with ammonium acetate (AA) and acetoacetanilide (AAA) indicator and is dried at 40 °C for 30 min. The formaldehyde sample is then dripped on the reaction zone and the μPAD is transferred to a hot plate in the portable detection system. A Hantzsch reaction is induced by heating the μPAD at 30 °C for 10 min. The resulting fluorescent formaldehyde-Acetoacetanilide complex (dihydropyridine derivative) is observed by a CMOS camera and the color image is transferred to a smartphone by means of a connector. Finally, the CH2O concentration is derived using self-written RGB color analysis mobile software implemented on the phone. The experimental results obtained using control samples with known CH2O concentrations in the range of 0.2–2.5 ppm show that the B (blue) fluorescence intensity (Y) and formaldehyde concentration (X) are related as Y = 29.455 X + 117.64. Moreover, the correlation coefficient is equal to R2 = 0.9937. The real-world applicability of the proposed detection platform is demonstrated by measuring the CH2O concentration in twelve commercial food samples. It is shown that the concentration measurements obtained using the proposed system deviate by no more than 6.2% from those obtained using a conventional spectrophotometric technique. Overall, the results presented in this study show that the proposed integrated microfluidic paper-based system provides a compact and reliable tool for low concentration CH2O measurement purposes.

Original languageEnglish
Pages (from-to)3623-3629
Number of pages7
JournalSensors and Actuators, B: Chemical
Volume255
DOIs
Publication statusPublished - 2018 Feb

Fingerprint

formaldehyde
Microfluidics
Formaldehyde
low concentrations
platforms
Color
Smartphones
color
connectors
food
correlation coefficients
Fluorescence
Cameras
acetates
Derivatives
CMOS
Heating
cameras
computer programs
fluorescence

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Instrumentation
  • Condensed Matter Physics
  • Surfaces, Coatings and Films
  • Metals and Alloys
  • Electrical and Electronic Engineering
  • Materials Chemistry

Cite this

Guzman, John Mello Camille C. ; Tayo, Lemmuel L. ; Liu, Chan Chiung ; Wang, Yao Nan ; Fu, Lung Ming. / Rapid microfluidic paper-based platform for low concentration formaldehyde detection. In: Sensors and Actuators, B: Chemical. 2018 ; Vol. 255. pp. 3623-3629.
@article{65976dbe69c44ecb9b6ace935bc7787e,
title = "Rapid microfluidic paper-based platform for low concentration formaldehyde detection",
abstract = "An integrated platform consisting of a microfluidic paper-based analytical device (μPAD) and a portable detection system is proposed for low concentration formaldehyde (CH2O) detection. In the proposed approach, the reaction zone of the μPAD is coated with ammonium acetate (AA) and acetoacetanilide (AAA) indicator and is dried at 40 °C for 30 min. The formaldehyde sample is then dripped on the reaction zone and the μPAD is transferred to a hot plate in the portable detection system. A Hantzsch reaction is induced by heating the μPAD at 30 °C for 10 min. The resulting fluorescent formaldehyde-Acetoacetanilide complex (dihydropyridine derivative) is observed by a CMOS camera and the color image is transferred to a smartphone by means of a connector. Finally, the CH2O concentration is derived using self-written RGB color analysis mobile software implemented on the phone. The experimental results obtained using control samples with known CH2O concentrations in the range of 0.2–2.5 ppm show that the B (blue) fluorescence intensity (Y) and formaldehyde concentration (X) are related as Y = 29.455 X + 117.64. Moreover, the correlation coefficient is equal to R2 = 0.9937. The real-world applicability of the proposed detection platform is demonstrated by measuring the CH2O concentration in twelve commercial food samples. It is shown that the concentration measurements obtained using the proposed system deviate by no more than 6.2{\%} from those obtained using a conventional spectrophotometric technique. Overall, the results presented in this study show that the proposed integrated microfluidic paper-based system provides a compact and reliable tool for low concentration CH2O measurement purposes.",
author = "Guzman, {John Mello Camille C.} and Tayo, {Lemmuel L.} and Liu, {Chan Chiung} and Wang, {Yao Nan} and Fu, {Lung Ming}",
year = "2018",
month = "2",
doi = "10.1016/j.snb.2017.09.080",
language = "English",
volume = "255",
pages = "3623--3629",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",

}

Rapid microfluidic paper-based platform for low concentration formaldehyde detection. / Guzman, John Mello Camille C.; Tayo, Lemmuel L.; Liu, Chan Chiung; Wang, Yao Nan; Fu, Lung Ming.

In: Sensors and Actuators, B: Chemical, Vol. 255, 02.2018, p. 3623-3629.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Rapid microfluidic paper-based platform for low concentration formaldehyde detection

AU - Guzman, John Mello Camille C.

AU - Tayo, Lemmuel L.

AU - Liu, Chan Chiung

AU - Wang, Yao Nan

AU - Fu, Lung Ming

PY - 2018/2

Y1 - 2018/2

N2 - An integrated platform consisting of a microfluidic paper-based analytical device (μPAD) and a portable detection system is proposed for low concentration formaldehyde (CH2O) detection. In the proposed approach, the reaction zone of the μPAD is coated with ammonium acetate (AA) and acetoacetanilide (AAA) indicator and is dried at 40 °C for 30 min. The formaldehyde sample is then dripped on the reaction zone and the μPAD is transferred to a hot plate in the portable detection system. A Hantzsch reaction is induced by heating the μPAD at 30 °C for 10 min. The resulting fluorescent formaldehyde-Acetoacetanilide complex (dihydropyridine derivative) is observed by a CMOS camera and the color image is transferred to a smartphone by means of a connector. Finally, the CH2O concentration is derived using self-written RGB color analysis mobile software implemented on the phone. The experimental results obtained using control samples with known CH2O concentrations in the range of 0.2–2.5 ppm show that the B (blue) fluorescence intensity (Y) and formaldehyde concentration (X) are related as Y = 29.455 X + 117.64. Moreover, the correlation coefficient is equal to R2 = 0.9937. The real-world applicability of the proposed detection platform is demonstrated by measuring the CH2O concentration in twelve commercial food samples. It is shown that the concentration measurements obtained using the proposed system deviate by no more than 6.2% from those obtained using a conventional spectrophotometric technique. Overall, the results presented in this study show that the proposed integrated microfluidic paper-based system provides a compact and reliable tool for low concentration CH2O measurement purposes.

AB - An integrated platform consisting of a microfluidic paper-based analytical device (μPAD) and a portable detection system is proposed for low concentration formaldehyde (CH2O) detection. In the proposed approach, the reaction zone of the μPAD is coated with ammonium acetate (AA) and acetoacetanilide (AAA) indicator and is dried at 40 °C for 30 min. The formaldehyde sample is then dripped on the reaction zone and the μPAD is transferred to a hot plate in the portable detection system. A Hantzsch reaction is induced by heating the μPAD at 30 °C for 10 min. The resulting fluorescent formaldehyde-Acetoacetanilide complex (dihydropyridine derivative) is observed by a CMOS camera and the color image is transferred to a smartphone by means of a connector. Finally, the CH2O concentration is derived using self-written RGB color analysis mobile software implemented on the phone. The experimental results obtained using control samples with known CH2O concentrations in the range of 0.2–2.5 ppm show that the B (blue) fluorescence intensity (Y) and formaldehyde concentration (X) are related as Y = 29.455 X + 117.64. Moreover, the correlation coefficient is equal to R2 = 0.9937. The real-world applicability of the proposed detection platform is demonstrated by measuring the CH2O concentration in twelve commercial food samples. It is shown that the concentration measurements obtained using the proposed system deviate by no more than 6.2% from those obtained using a conventional spectrophotometric technique. Overall, the results presented in this study show that the proposed integrated microfluidic paper-based system provides a compact and reliable tool for low concentration CH2O measurement purposes.

UR - http://www.scopus.com/inward/record.url?scp=85029652677&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85029652677&partnerID=8YFLogxK

U2 - 10.1016/j.snb.2017.09.080

DO - 10.1016/j.snb.2017.09.080

M3 - Article

AN - SCOPUS:85029652677

VL - 255

SP - 3623

EP - 3629

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

ER -