Removal and recovery of lead fixed-bed biosorption with immobilized bacterial biomass

Jo-Shu Chang, Jeng Charn Huang, Chia Cheng Chang, Tsueng Jeng Tarn

Research output: Contribution to journalConference article

25 Citations (Scopus)

Abstract

Fixed-bed columns packed with immobilized biomass of Pseudomonas aeruginosa PU21 were utilized to remove lead (Pb) from the contaminated water. Effects of the immobilization method, bed length, flow rate, and the particle size on the performance of Pb removal by the biosorption columns were systematically investigated. Calcium alginate-immobilized cells were found to hold better Pb capacity than polyacrylamide (PAA)-entrapped cells. Typical saturation capacity of calcium alginate (CA)-immobilized cells was 280 mg Pb/g, and 31 mg Pb/g for PAA-immobilized cells. Results of fixed-bed biosorption showed that the breakthrough time (t(b)) appeared to increase with the bed length, but decreased with the flow rate. The typical overall adsorption efficiency (Q) was within 50-60%, and did not appreciably fluctuate with changes in the operation conditions or the particle size. The initial rate of adsorption was facilitated nearly 40% as the size of immobilized cells was reduced from 3.5 mm to 2 mm, whereas the particle size did not affect the equilibrium adsorption of the immobilized biomass. The length of unused bed (LUB) remained constant with different bed length, while it slightly increased with the raising of the Pb loading rate. The metal-laden column was regenerated by elution of HCl solution (pH 2.0). For up to four adsorption/desorption (A/D) cycles, the metal recovery efficiency of each cycle was over 98%, and the recovery ratio was 8:1 and 27:1 for PAA and CA-immobilized cells, respectively. The regenerated beds were able to restore over 66% of their original adsorption capacity after four successive A/D cycles.

Original languageEnglish
Pages (from-to)171-178
Number of pages8
JournalWater Science and Technology
Volume38
Issue number4-5 -5 pt 4
DOIs
Publication statusPublished - 1998 Dec 2
EventProceedings of the 1998 19th Biennial Conference of the International Association on Water Quality. Part 1 (of 9) - Vancouver, Can
Duration: 1998 Jun 211998 Jun 26

Fingerprint

Biosorption
Biomass
Lead
adsorption
Adsorption
Recovery
Cells
alginate
Alginate
biomass
Polyacrylates
Calcium
calcium
Particle size
particle size
Desorption
desorption
Flow rate
Metal recovery
metal

All Science Journal Classification (ASJC) codes

  • Environmental Engineering
  • Water Science and Technology

Cite this

Chang, Jo-Shu ; Huang, Jeng Charn ; Chang, Chia Cheng ; Tarn, Tsueng Jeng. / Removal and recovery of lead fixed-bed biosorption with immobilized bacterial biomass. In: Water Science and Technology. 1998 ; Vol. 38, No. 4-5 -5 pt 4. pp. 171-178.
@article{958f430218d94e06914129ea3c0a6077,
title = "Removal and recovery of lead fixed-bed biosorption with immobilized bacterial biomass",
abstract = "Fixed-bed columns packed with immobilized biomass of Pseudomonas aeruginosa PU21 were utilized to remove lead (Pb) from the contaminated water. Effects of the immobilization method, bed length, flow rate, and the particle size on the performance of Pb removal by the biosorption columns were systematically investigated. Calcium alginate-immobilized cells were found to hold better Pb capacity than polyacrylamide (PAA)-entrapped cells. Typical saturation capacity of calcium alginate (CA)-immobilized cells was 280 mg Pb/g, and 31 mg Pb/g for PAA-immobilized cells. Results of fixed-bed biosorption showed that the breakthrough time (t(b)) appeared to increase with the bed length, but decreased with the flow rate. The typical overall adsorption efficiency (Q) was within 50-60{\%}, and did not appreciably fluctuate with changes in the operation conditions or the particle size. The initial rate of adsorption was facilitated nearly 40{\%} as the size of immobilized cells was reduced from 3.5 mm to 2 mm, whereas the particle size did not affect the equilibrium adsorption of the immobilized biomass. The length of unused bed (LUB) remained constant with different bed length, while it slightly increased with the raising of the Pb loading rate. The metal-laden column was regenerated by elution of HCl solution (pH 2.0). For up to four adsorption/desorption (A/D) cycles, the metal recovery efficiency of each cycle was over 98{\%}, and the recovery ratio was 8:1 and 27:1 for PAA and CA-immobilized cells, respectively. The regenerated beds were able to restore over 66{\%} of their original adsorption capacity after four successive A/D cycles.",
author = "Jo-Shu Chang and Huang, {Jeng Charn} and Chang, {Chia Cheng} and Tarn, {Tsueng Jeng}",
year = "1998",
month = "12",
day = "2",
doi = "10.1016/S0273-1223(98)00526-5",
language = "English",
volume = "38",
pages = "171--178",
journal = "Water Science and Technology",
issn = "0273-1223",
publisher = "IWA Publishing",
number = "4-5 -5 pt 4",

}

Removal and recovery of lead fixed-bed biosorption with immobilized bacterial biomass. / Chang, Jo-Shu; Huang, Jeng Charn; Chang, Chia Cheng; Tarn, Tsueng Jeng.

In: Water Science and Technology, Vol. 38, No. 4-5 -5 pt 4, 02.12.1998, p. 171-178.

Research output: Contribution to journalConference article

TY - JOUR

T1 - Removal and recovery of lead fixed-bed biosorption with immobilized bacterial biomass

AU - Chang, Jo-Shu

AU - Huang, Jeng Charn

AU - Chang, Chia Cheng

AU - Tarn, Tsueng Jeng

PY - 1998/12/2

Y1 - 1998/12/2

N2 - Fixed-bed columns packed with immobilized biomass of Pseudomonas aeruginosa PU21 were utilized to remove lead (Pb) from the contaminated water. Effects of the immobilization method, bed length, flow rate, and the particle size on the performance of Pb removal by the biosorption columns were systematically investigated. Calcium alginate-immobilized cells were found to hold better Pb capacity than polyacrylamide (PAA)-entrapped cells. Typical saturation capacity of calcium alginate (CA)-immobilized cells was 280 mg Pb/g, and 31 mg Pb/g for PAA-immobilized cells. Results of fixed-bed biosorption showed that the breakthrough time (t(b)) appeared to increase with the bed length, but decreased with the flow rate. The typical overall adsorption efficiency (Q) was within 50-60%, and did not appreciably fluctuate with changes in the operation conditions or the particle size. The initial rate of adsorption was facilitated nearly 40% as the size of immobilized cells was reduced from 3.5 mm to 2 mm, whereas the particle size did not affect the equilibrium adsorption of the immobilized biomass. The length of unused bed (LUB) remained constant with different bed length, while it slightly increased with the raising of the Pb loading rate. The metal-laden column was regenerated by elution of HCl solution (pH 2.0). For up to four adsorption/desorption (A/D) cycles, the metal recovery efficiency of each cycle was over 98%, and the recovery ratio was 8:1 and 27:1 for PAA and CA-immobilized cells, respectively. The regenerated beds were able to restore over 66% of their original adsorption capacity after four successive A/D cycles.

AB - Fixed-bed columns packed with immobilized biomass of Pseudomonas aeruginosa PU21 were utilized to remove lead (Pb) from the contaminated water. Effects of the immobilization method, bed length, flow rate, and the particle size on the performance of Pb removal by the biosorption columns were systematically investigated. Calcium alginate-immobilized cells were found to hold better Pb capacity than polyacrylamide (PAA)-entrapped cells. Typical saturation capacity of calcium alginate (CA)-immobilized cells was 280 mg Pb/g, and 31 mg Pb/g for PAA-immobilized cells. Results of fixed-bed biosorption showed that the breakthrough time (t(b)) appeared to increase with the bed length, but decreased with the flow rate. The typical overall adsorption efficiency (Q) was within 50-60%, and did not appreciably fluctuate with changes in the operation conditions or the particle size. The initial rate of adsorption was facilitated nearly 40% as the size of immobilized cells was reduced from 3.5 mm to 2 mm, whereas the particle size did not affect the equilibrium adsorption of the immobilized biomass. The length of unused bed (LUB) remained constant with different bed length, while it slightly increased with the raising of the Pb loading rate. The metal-laden column was regenerated by elution of HCl solution (pH 2.0). For up to four adsorption/desorption (A/D) cycles, the metal recovery efficiency of each cycle was over 98%, and the recovery ratio was 8:1 and 27:1 for PAA and CA-immobilized cells, respectively. The regenerated beds were able to restore over 66% of their original adsorption capacity after four successive A/D cycles.

UR - http://www.scopus.com/inward/record.url?scp=0031766912&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031766912&partnerID=8YFLogxK

U2 - 10.1016/S0273-1223(98)00526-5

DO - 10.1016/S0273-1223(98)00526-5

M3 - Conference article

AN - SCOPUS:0031766912

VL - 38

SP - 171

EP - 178

JO - Water Science and Technology

JF - Water Science and Technology

SN - 0273-1223

IS - 4-5 -5 pt 4