This paper presents the development and application of a miniaturized impedance sensing system for a single cell impedance measurement. The system includes a set of plane electrodes on a biochip, a function generator, an impedance analyzer and a handheld microscope. The system also equips a programmable controller for the automatic impedance measurement and analysis. It can execute the cell located and cell measured by effects of dielectrophoresis (DEP) and alternating electrothermal (ACET).

Original languageEnglish
Title of host publication2012 6th International Conference on Sensing Technology, ICST 2012
Pages682-687
Number of pages6
DOIs
Publication statusPublished - 2012 Dec 1
Event2012 6th International Conference on Sensing Technology, ICST 2012 - Kolkata, India
Duration: 2012 Dec 182012 Dec 21

Publication series

NameProceedings of the International Conference on Sensing Technology, ICST
ISSN (Print)2156-8065
ISSN (Electronic)2156-8073

Other

Other2012 6th International Conference on Sensing Technology, ICST 2012
CountryIndia
CityKolkata
Period12-12-1812-12-21

Fingerprint

Function generators
Biochips
Programmable logic controllers
Electrophoresis
Microscopes
Electrodes

All Science Journal Classification (ASJC) codes

  • Artificial Intelligence
  • Computer Science Applications
  • Signal Processing
  • Electrical and Electronic Engineering

Cite this

Tsai, S. L., Chen, M. K., Wang, M. H., & Jang, L-S. (2012). Single cell measurement using the portable impedance analyzer. In 2012 6th International Conference on Sensing Technology, ICST 2012 (pp. 682-687). [6461764] (Proceedings of the International Conference on Sensing Technology, ICST). https://doi.org/10.1109/ICSensT.2012.6461764
Tsai, Sung Lin ; Chen, Ming Kun ; Wang, Min Haw ; Jang, Ling-Sheng. / Single cell measurement using the portable impedance analyzer. 2012 6th International Conference on Sensing Technology, ICST 2012. 2012. pp. 682-687 (Proceedings of the International Conference on Sensing Technology, ICST).
@inproceedings{f23c6defb96b48e9a1580f3213563f12,
title = "Single cell measurement using the portable impedance analyzer",
abstract = "This paper presents the development and application of a miniaturized impedance sensing system for a single cell impedance measurement. The system includes a set of plane electrodes on a biochip, a function generator, an impedance analyzer and a handheld microscope. The system also equips a programmable controller for the automatic impedance measurement and analysis. It can execute the cell located and cell measured by effects of dielectrophoresis (DEP) and alternating electrothermal (ACET).",
author = "Tsai, {Sung Lin} and Chen, {Ming Kun} and Wang, {Min Haw} and Ling-Sheng Jang",
year = "2012",
month = "12",
day = "1",
doi = "10.1109/ICSensT.2012.6461764",
language = "English",
isbn = "9781467322485",
series = "Proceedings of the International Conference on Sensing Technology, ICST",
pages = "682--687",
booktitle = "2012 6th International Conference on Sensing Technology, ICST 2012",

}

Tsai, SL, Chen, MK, Wang, MH & Jang, L-S 2012, Single cell measurement using the portable impedance analyzer. in 2012 6th International Conference on Sensing Technology, ICST 2012., 6461764, Proceedings of the International Conference on Sensing Technology, ICST, pp. 682-687, 2012 6th International Conference on Sensing Technology, ICST 2012, Kolkata, India, 12-12-18. https://doi.org/10.1109/ICSensT.2012.6461764

Single cell measurement using the portable impedance analyzer. / Tsai, Sung Lin; Chen, Ming Kun; Wang, Min Haw; Jang, Ling-Sheng.

2012 6th International Conference on Sensing Technology, ICST 2012. 2012. p. 682-687 6461764 (Proceedings of the International Conference on Sensing Technology, ICST).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - Single cell measurement using the portable impedance analyzer

AU - Tsai, Sung Lin

AU - Chen, Ming Kun

AU - Wang, Min Haw

AU - Jang, Ling-Sheng

PY - 2012/12/1

Y1 - 2012/12/1

N2 - This paper presents the development and application of a miniaturized impedance sensing system for a single cell impedance measurement. The system includes a set of plane electrodes on a biochip, a function generator, an impedance analyzer and a handheld microscope. The system also equips a programmable controller for the automatic impedance measurement and analysis. It can execute the cell located and cell measured by effects of dielectrophoresis (DEP) and alternating electrothermal (ACET).

AB - This paper presents the development and application of a miniaturized impedance sensing system for a single cell impedance measurement. The system includes a set of plane electrodes on a biochip, a function generator, an impedance analyzer and a handheld microscope. The system also equips a programmable controller for the automatic impedance measurement and analysis. It can execute the cell located and cell measured by effects of dielectrophoresis (DEP) and alternating electrothermal (ACET).

UR - http://www.scopus.com/inward/record.url?scp=84874732585&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84874732585&partnerID=8YFLogxK

U2 - 10.1109/ICSensT.2012.6461764

DO - 10.1109/ICSensT.2012.6461764

M3 - Conference contribution

SN - 9781467322485

T3 - Proceedings of the International Conference on Sensing Technology, ICST

SP - 682

EP - 687

BT - 2012 6th International Conference on Sensing Technology, ICST 2012

ER -

Tsai SL, Chen MK, Wang MH, Jang L-S. Single cell measurement using the portable impedance analyzer. In 2012 6th International Conference on Sensing Technology, ICST 2012. 2012. p. 682-687. 6461764. (Proceedings of the International Conference on Sensing Technology, ICST). https://doi.org/10.1109/ICSensT.2012.6461764