Special field measurement results of an onshore wind farm connected to power grid of Taiwan power system subject to Typhoon Matmo

Li Wang, Shun Chin Ke, Ting Wei Hong, Chien Hsiang Yu, Chuan Chieh Yeh, Wei Sheng Liu, Bing Lin Kuan, Xiu Yu Lu, Hong Yi Wu, Anton Victorovich Prokhorov

Research output: Contribution to journalArticle

Abstract

This paper studies and analyzes the power-quality measurement results due to the special operating characteristics of the wind turbines of a commercial onshore wind farm connected to the power grid of Taiwan Power System when Typhoon Matmo passed through Taiwan. This Kuan-Yuan onshore wind farm of 28.5 MW with 19 1.5-MW wind-turbine generator (WTG) based on doubly fed induction generator is connected to Kuan-Yin primary substation through two of four step-up main transformers of 161/69 kV, 200 MVA. The measured data were recorded from July 22, 2014 to July 29, 2014 for total seven days. During the measurement period, Typhoon Matmo just passed through Taiwan and the 19 WTGs were forced to stop. The power-quality measurement results due to the special operating characteristics of the wind turbines of the studied Kuan-Yuan wind farm subject to Typhoon Matmo were also recorded and studied. According to the measured results, the power quality of the studied Kuan-Yuan onshore wind farm during the measurement period can meet the grid code of Taiwan Power Company except the voltage flicker of ΔV10. The relationships of the recorded times and dates between the measured electrical quantities and power-quality results of the studied onshore wind farm and the Typhoon Matmo passed through Taiwan are also discussed.

Original languageEnglish
Article number8444095
Pages (from-to)158-166
Number of pages9
JournalIEEE Transactions on Industry Applications
Volume55
Issue number1
DOIs
Publication statusPublished - 2019 Jan 1

Fingerprint

Onshore wind farms
Power quality
Wind turbines
Asynchronous generators
Turbogenerators
Electric potential
Industry

All Science Journal Classification (ASJC) codes

  • Control and Systems Engineering
  • Industrial and Manufacturing Engineering
  • Electrical and Electronic Engineering

Cite this

Wang, Li ; Ke, Shun Chin ; Hong, Ting Wei ; Yu, Chien Hsiang ; Yeh, Chuan Chieh ; Liu, Wei Sheng ; Kuan, Bing Lin ; Lu, Xiu Yu ; Wu, Hong Yi ; Prokhorov, Anton Victorovich. / Special field measurement results of an onshore wind farm connected to power grid of Taiwan power system subject to Typhoon Matmo. In: IEEE Transactions on Industry Applications. 2019 ; Vol. 55, No. 1. pp. 158-166.
@article{d1a37813eabc43939afa5291909a9e73,
title = "Special field measurement results of an onshore wind farm connected to power grid of Taiwan power system subject to Typhoon Matmo",
abstract = "This paper studies and analyzes the power-quality measurement results due to the special operating characteristics of the wind turbines of a commercial onshore wind farm connected to the power grid of Taiwan Power System when Typhoon Matmo passed through Taiwan. This Kuan-Yuan onshore wind farm of 28.5 MW with 19 1.5-MW wind-turbine generator (WTG) based on doubly fed induction generator is connected to Kuan-Yin primary substation through two of four step-up main transformers of 161/69 kV, 200 MVA. The measured data were recorded from July 22, 2014 to July 29, 2014 for total seven days. During the measurement period, Typhoon Matmo just passed through Taiwan and the 19 WTGs were forced to stop. The power-quality measurement results due to the special operating characteristics of the wind turbines of the studied Kuan-Yuan wind farm subject to Typhoon Matmo were also recorded and studied. According to the measured results, the power quality of the studied Kuan-Yuan onshore wind farm during the measurement period can meet the grid code of Taiwan Power Company except the voltage flicker of ΔV10. The relationships of the recorded times and dates between the measured electrical quantities and power-quality results of the studied onshore wind farm and the Typhoon Matmo passed through Taiwan are also discussed.",
author = "Li Wang and Ke, {Shun Chin} and Hong, {Ting Wei} and Yu, {Chien Hsiang} and Yeh, {Chuan Chieh} and Liu, {Wei Sheng} and Kuan, {Bing Lin} and Lu, {Xiu Yu} and Wu, {Hong Yi} and Prokhorov, {Anton Victorovich}",
year = "2019",
month = "1",
day = "1",
doi = "10.1109/TIA.2018.2866579",
language = "English",
volume = "55",
pages = "158--166",
journal = "IEEE Transactions on Industry Applications",
issn = "0093-9994",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "1",

}

Special field measurement results of an onshore wind farm connected to power grid of Taiwan power system subject to Typhoon Matmo. / Wang, Li; Ke, Shun Chin; Hong, Ting Wei; Yu, Chien Hsiang; Yeh, Chuan Chieh; Liu, Wei Sheng; Kuan, Bing Lin; Lu, Xiu Yu; Wu, Hong Yi; Prokhorov, Anton Victorovich.

In: IEEE Transactions on Industry Applications, Vol. 55, No. 1, 8444095, 01.01.2019, p. 158-166.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Special field measurement results of an onshore wind farm connected to power grid of Taiwan power system subject to Typhoon Matmo

AU - Wang, Li

AU - Ke, Shun Chin

AU - Hong, Ting Wei

AU - Yu, Chien Hsiang

AU - Yeh, Chuan Chieh

AU - Liu, Wei Sheng

AU - Kuan, Bing Lin

AU - Lu, Xiu Yu

AU - Wu, Hong Yi

AU - Prokhorov, Anton Victorovich

PY - 2019/1/1

Y1 - 2019/1/1

N2 - This paper studies and analyzes the power-quality measurement results due to the special operating characteristics of the wind turbines of a commercial onshore wind farm connected to the power grid of Taiwan Power System when Typhoon Matmo passed through Taiwan. This Kuan-Yuan onshore wind farm of 28.5 MW with 19 1.5-MW wind-turbine generator (WTG) based on doubly fed induction generator is connected to Kuan-Yin primary substation through two of four step-up main transformers of 161/69 kV, 200 MVA. The measured data were recorded from July 22, 2014 to July 29, 2014 for total seven days. During the measurement period, Typhoon Matmo just passed through Taiwan and the 19 WTGs were forced to stop. The power-quality measurement results due to the special operating characteristics of the wind turbines of the studied Kuan-Yuan wind farm subject to Typhoon Matmo were also recorded and studied. According to the measured results, the power quality of the studied Kuan-Yuan onshore wind farm during the measurement period can meet the grid code of Taiwan Power Company except the voltage flicker of ΔV10. The relationships of the recorded times and dates between the measured electrical quantities and power-quality results of the studied onshore wind farm and the Typhoon Matmo passed through Taiwan are also discussed.

AB - This paper studies and analyzes the power-quality measurement results due to the special operating characteristics of the wind turbines of a commercial onshore wind farm connected to the power grid of Taiwan Power System when Typhoon Matmo passed through Taiwan. This Kuan-Yuan onshore wind farm of 28.5 MW with 19 1.5-MW wind-turbine generator (WTG) based on doubly fed induction generator is connected to Kuan-Yin primary substation through two of four step-up main transformers of 161/69 kV, 200 MVA. The measured data were recorded from July 22, 2014 to July 29, 2014 for total seven days. During the measurement period, Typhoon Matmo just passed through Taiwan and the 19 WTGs were forced to stop. The power-quality measurement results due to the special operating characteristics of the wind turbines of the studied Kuan-Yuan wind farm subject to Typhoon Matmo were also recorded and studied. According to the measured results, the power quality of the studied Kuan-Yuan onshore wind farm during the measurement period can meet the grid code of Taiwan Power Company except the voltage flicker of ΔV10. The relationships of the recorded times and dates between the measured electrical quantities and power-quality results of the studied onshore wind farm and the Typhoon Matmo passed through Taiwan are also discussed.

UR - http://www.scopus.com/inward/record.url?scp=85052715461&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85052715461&partnerID=8YFLogxK

U2 - 10.1109/TIA.2018.2866579

DO - 10.1109/TIA.2018.2866579

M3 - Article

AN - SCOPUS:85052715461

VL - 55

SP - 158

EP - 166

JO - IEEE Transactions on Industry Applications

JF - IEEE Transactions on Industry Applications

SN - 0093-9994

IS - 1

M1 - 8444095

ER -