Study of common-mode voltage measurements for IEC62684

Ray-Lee Lin, Jhen Yuan Guo, Chih Ming Chang

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

This paper presents the study of common-mode (CM) voltage measurements for IEC62684 regulatory. Due to the digitization error caused by the limited vertical bit number of the analog-to-digital converter (ADC) in oscilloscopes, the CM voltage spectrum measurement of the flyback converter with ac source occurs significant inaccuracy. In order to avoid the digitization error, the CM voltage measurement of the flyback converter with dc source is proposed in this paper. The simplified equivalent circuits of the flyback converter with ac and dc input sources are derived to calculate the ratio of their CM voltages. With 64-bit circuit simulation software SIMPLIS, the digitization error can be significantly reduced to have high-resolution measurements for the verification of the calculated CM voltage ratio. The ratio of the calculated CM voltages can be used to modify the measurement result with dc source to obtain the equivalent result with ac source.

Original languageEnglish
Article number6766652
Pages (from-to)2976-2984
Number of pages9
JournalIEEE Transactions on Industry Applications
Volume50
Issue number5
DOIs
Publication statusPublished - 2014 Sep 1

All Science Journal Classification (ASJC) codes

  • Control and Systems Engineering
  • Industrial and Manufacturing Engineering
  • Electrical and Electronic Engineering

Fingerprint Dive into the research topics of 'Study of common-mode voltage measurements for IEC62684'. Together they form a unique fingerprint.

Cite this