Abstract

The purpose of this study is to realize a non-condensing environment by developing a new type of desiccant air-conditioning system with lower energy consumption. In this paper, the authors studied several types of desiccant air-conditioning systems which are combined with CO_2 heat pumps, and the systems are considered to be adapted as outdoor air conditioning systems in hotel buildings. The overall energy efficiency of the proposed systems (the combined system) is compared with those of the conventional outdoor air-conditioning systems. The results show that the system COP of the proposed systems has a value of 2.1〜2.2, which is less than the conventional air-conditioning system with a total heat exchanger, but is a very substantial increase in energy efficiency compared with a conventional desiccant cooling system and a conventional outdoor air-conditioning system under the conditions of no-condensing inside the indoor cooling units.
Original languageOther
Pages (from-to)51-57
Journal空気調和・衛生工学会学論文集
Volume146
DOIs
Publication statusPublished - 2006

Fingerprint

Air conditioning
Pumps
Energy efficiency
Hotels
Cooling systems
Heat exchangers
Hot Temperature
Enthalpy
Energy utilization
Cooling

All Science Journal Classification (ASJC) codes

  • Architecture

Cite this

@article{932069a5a9c84247aefd2aff06e9aa24,
title = "非結露型次世代空調システムに関する研究: 第2報― CO2ヒートポンプを組み込んだデシカント外調機システムの実用化に関する検討",
abstract = "The purpose of this study is to realize a non-condensing environment by developing a new type of desiccant air-conditioning system with lower energy consumption. In this paper, the authors studied several types of desiccant air-conditioning systems which are combined with CO_2 heat pumps, and the systems are considered to be adapted as outdoor air conditioning systems in hotel buildings. The overall energy efficiency of the proposed systems (the combined system) is compared with those of the conventional outdoor air-conditioning systems. The results show that the system COP of the proposed systems has a value of 2.1〜2.2, which is less than the conventional air-conditioning system with a total heat exchanger, but is a very substantial increase in energy efficiency compared with a conventional desiccant cooling system and a conventional outdoor air-conditioning system under the conditions of no-condensing inside the indoor cooling units.",
author = "Yaw-Shyan Tsay",
year = "2006",
doi = "10.18948/shase.31.116_51",
language = "Other",
volume = "146",
pages = "51--57",
journal = "空気調和・衛生工学会学論文集",
issn = "0385-275X",

}

TY - JOUR

T1 - 非結露型次世代空調システムに関する研究

T2 - 第2報― CO2ヒートポンプを組み込んだデシカント外調機システムの実用化に関する検討

AU - Tsay, Yaw-Shyan

PY - 2006

Y1 - 2006

N2 - The purpose of this study is to realize a non-condensing environment by developing a new type of desiccant air-conditioning system with lower energy consumption. In this paper, the authors studied several types of desiccant air-conditioning systems which are combined with CO_2 heat pumps, and the systems are considered to be adapted as outdoor air conditioning systems in hotel buildings. The overall energy efficiency of the proposed systems (the combined system) is compared with those of the conventional outdoor air-conditioning systems. The results show that the system COP of the proposed systems has a value of 2.1〜2.2, which is less than the conventional air-conditioning system with a total heat exchanger, but is a very substantial increase in energy efficiency compared with a conventional desiccant cooling system and a conventional outdoor air-conditioning system under the conditions of no-condensing inside the indoor cooling units.

AB - The purpose of this study is to realize a non-condensing environment by developing a new type of desiccant air-conditioning system with lower energy consumption. In this paper, the authors studied several types of desiccant air-conditioning systems which are combined with CO_2 heat pumps, and the systems are considered to be adapted as outdoor air conditioning systems in hotel buildings. The overall energy efficiency of the proposed systems (the combined system) is compared with those of the conventional outdoor air-conditioning systems. The results show that the system COP of the proposed systems has a value of 2.1〜2.2, which is less than the conventional air-conditioning system with a total heat exchanger, but is a very substantial increase in energy efficiency compared with a conventional desiccant cooling system and a conventional outdoor air-conditioning system under the conditions of no-condensing inside the indoor cooling units.

U2 - 10.18948/shase.31.116_51

DO - 10.18948/shase.31.116_51

M3 - Article

VL - 146

SP - 51

EP - 57

JO - 空気調和・衛生工学会学論文集

JF - 空気調和・衛生工学会学論文集

SN - 0385-275X

ER -