TY - JOUR
T1 - Suture anchor versus screw fixation for greater tuberosity fractures of the humerus--a biomechanical study.
AU - Lin, Cheng Li
AU - Hong, Chih Kai
AU - Jou, I. Ming
AU - Lin, Chii Jeng
AU - Su, Fong Chin
AU - Su, Wei Ren
PY - 2012/3
Y1 - 2012/3
N2 - Suture anchors and screws are commonly used for fixation of humeral greater tuberosity (GT) fractures in either arthroscopic or open surgeries, but no biomechanical studies have been performed to compare the strength of fixation constructs using these two implants. This cadaveric study aimed to compare the biomechanical strength of three different fixation constructs in the management of GT fractures: Double-Row Suture Anchor Fixation (DR); Suture-Bridge Technique using suture anchors and knotless suture anchors (SB); and Two-Screw Fixation (TS). The experimental procedure was designed to assess fracture displacement after cyclic loading, failure load, and failure mode of the fixation construct. Significant differences were found among the SB (321 N), DR (263 N), and TS (187 N) groups (SB > DR > TS, p < 0.05) in the mean force of cyclic loading to create 3 mm displacement. Regarding the mean force of cyclic loading to create 5 mm displacement and ultimate failure load, no significant difference was found between the DR (370 N, 480 N) and SB (399 N, 493 N) groups, but both groups achieved superior results compared with the TS group (249 N, 340 N) (p < 0.05). The results suggested that the suture anchor constructs would be stronger than the fixation construct using screws for the humeral GT fracture.
AB - Suture anchors and screws are commonly used for fixation of humeral greater tuberosity (GT) fractures in either arthroscopic or open surgeries, but no biomechanical studies have been performed to compare the strength of fixation constructs using these two implants. This cadaveric study aimed to compare the biomechanical strength of three different fixation constructs in the management of GT fractures: Double-Row Suture Anchor Fixation (DR); Suture-Bridge Technique using suture anchors and knotless suture anchors (SB); and Two-Screw Fixation (TS). The experimental procedure was designed to assess fracture displacement after cyclic loading, failure load, and failure mode of the fixation construct. Significant differences were found among the SB (321 N), DR (263 N), and TS (187 N) groups (SB > DR > TS, p < 0.05) in the mean force of cyclic loading to create 3 mm displacement. Regarding the mean force of cyclic loading to create 5 mm displacement and ultimate failure load, no significant difference was found between the DR (370 N, 480 N) and SB (399 N, 493 N) groups, but both groups achieved superior results compared with the TS group (249 N, 340 N) (p < 0.05). The results suggested that the suture anchor constructs would be stronger than the fixation construct using screws for the humeral GT fracture.
UR - http://www.scopus.com/inward/record.url?scp=84873033230&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84873033230&partnerID=8YFLogxK
U2 - 10.1002/jor.21530
DO - 10.1002/jor.21530
M3 - Article
C2 - 21858857
AN - SCOPUS:84873033230
SN - 0736-0266
VL - 30
SP - 423
EP - 428
JO - Journal of orthopaedic research : official publication of the Orthopaedic Research Society
JF - Journal of orthopaedic research : official publication of the Orthopaedic Research Society
IS - 3
ER -