Temporal focusing multiphoton microscopy with optimized parallel multiline scanning for fast biotissue imaging

Chia Yuan Chang, Chun Yun Lin, Yvonne Y. Hu, Sheng Feng Tsai, Feng Chun Hsu, Shean Jen Chen

Research output: Contribution to journalArticlepeer-review

3 Citations (Scopus)

Abstract

Significance: Line scanning-based temporal focusing multiphoton microscopy (TFMPM) has superior axial excitation confinement (AEC) compared to conventional widefield TFMPM, but the frame rate is limited due to the limitation of the single line-To-line scanning mechanism. The development of the multiline scanning-based TFMPM requires only eight multiline patterns for full-field uniform multiphoton excitation and it still maintains superior AEC. Aim: The optimized parallel multiline scanning TFMPM is developed, and the performance is verified with theoretical simulation. The system provides a sharp AEC equivalent to the line scanning-based TFMPM, but fewer scans are required. Approach: A digital micromirror device is integrated in the TFMPM system and generates the multiline pattern for excitation. Based on the result of single-line pattern with sharp AEC, we can further model the multiline pattern to find the best structure that has the highest duty cycle together with the best AEC performance. Results: The AEC is experimentally improved to 1.7 μm from the 3.5 μm of conventional TFMPM. The adopted multiline pattern is akin to a pulse-width-modulation pattern with a spatial period of four times the diffraction-limited line width. In other words, ideally only four π / 2 spatial phase-shift scans are required to form a full two-dimensional image with superior AEC instead of image-size-dependent line-To-line scanning. Conclusions: We have demonstrated the developed parallel multiline scanning-based TFMPM has the multiline pattern for sharp AEC and the least scans required for full-field uniform excitation. In the experimental results, the temporal focusing-based multiphoton images of disordered biotissue of mouse skin with improved axial resolution due to the near-Theoretical limit AEC are shown to clearly reduce background scattering.

Original languageEnglish
Article number016501
JournalJournal of Biomedical Optics
Volume26
Issue number1
DOIs
Publication statusPublished - 2021 Jan 31

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Biomaterials
  • Biomedical Engineering

Fingerprint

Dive into the research topics of 'Temporal focusing multiphoton microscopy with optimized parallel multiline scanning for fast biotissue imaging'. Together they form a unique fingerprint.

Cite this