TY - JOUR
T1 - Tendon Surface Modification by Chemically Modified HA Coating after Flexor Digitorum Profundus Tendon Repair
AU - Yang, Chao
AU - Amadio, Peter C.
AU - Sun, Yu Iong
AU - Zhao, Chunfeng
AU - Zobitz, Mark E.
AU - An, Kai Nan
PY - 2004/1/15
Y1 - 2004/1/15
N2 - Carbodiimide derivatized HA (cd-HA) is less soluble in water than normal HA, and therefore has an increased tissue residence time. The purpose of this study was to study the effect of cd-HA gel on gliding and repair integrity during simulated repetitive motion of a repaired tendon in vitro. A total of 36 flexor digitorum profundus (FDP) tendons from six adult mongrel dogs were used and divided into three groups of control, simple HA, and cd-HA. The gliding resistance between the FDP and the proximal pulley, FDS, and bone was measured before laceration and after modified Kessler technique repair at 1, 5, 10, 50, 100, 200, 300, 400, and 500 cycles. After gliding testing, failure load, tendon stiffness, and resistance to gap formation were measured. The results showed from the first cycle to the 10th cycle, there were no significant differences in gliding resistance between the three testing groups (p > 0.05). From the 50th cycle onwards, the friction was significantly lower in the cd-HA gel group than in the control group (p < 0.05). Neither breaking strength, nor tendon stiffness, nor resistance to gap formation of the repairs were significantly different between the three groups (p > 0.05).
AB - Carbodiimide derivatized HA (cd-HA) is less soluble in water than normal HA, and therefore has an increased tissue residence time. The purpose of this study was to study the effect of cd-HA gel on gliding and repair integrity during simulated repetitive motion of a repaired tendon in vitro. A total of 36 flexor digitorum profundus (FDP) tendons from six adult mongrel dogs were used and divided into three groups of control, simple HA, and cd-HA. The gliding resistance between the FDP and the proximal pulley, FDS, and bone was measured before laceration and after modified Kessler technique repair at 1, 5, 10, 50, 100, 200, 300, 400, and 500 cycles. After gliding testing, failure load, tendon stiffness, and resistance to gap formation were measured. The results showed from the first cycle to the 10th cycle, there were no significant differences in gliding resistance between the three testing groups (p > 0.05). From the 50th cycle onwards, the friction was significantly lower in the cd-HA gel group than in the control group (p < 0.05). Neither breaking strength, nor tendon stiffness, nor resistance to gap formation of the repairs were significantly different between the three groups (p > 0.05).
UR - http://www.scopus.com/inward/record.url?scp=0346095339&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0346095339&partnerID=8YFLogxK
U2 - 10.1002/jbm.b.10074
DO - 10.1002/jbm.b.10074
M3 - Article
C2 - 14689491
AN - SCOPUS:0346095339
SN - 0021-9304
VL - 68
SP - 15
EP - 20
JO - Journal of Biomedical Materials Research - Part B Applied Biomaterials
JF - Journal of Biomedical Materials Research - Part B Applied Biomaterials
IS - 1
ER -