The purpose of this study was to describe a modification of the Massachusetts General Hospital (MMGH) tendon repair and to compare it with three other suture techniques. Twenty human flexor digitorum profundus (FDP) tendons were randomly assigned to the modified Pennington (MP) suture and the MMGH suture. These were compared to the modified Kessler (MK) and Massachusetts General Hospital (MGH) sutures, using data from a previous study. All tendons were repaired with a similar epitendinous stitch and core sutures of 4-0 FiberWire. There was no significant difference in the normalized gliding resistance within the two-strand or four-strand core repair groups. The MP suture had significantly higher 2 mm gap force and ultimate load to failure than the MK suture. The MMGH suture had significantly higher 2 mm gap force and maximum failure ultimate load than the MGH suture. All repairs failed by knot unravelling.
Original language | English |
---|---|
Pages (from-to) | 316-322 |
Number of pages | 7 |
Journal | Journal of Hand Surgery: European Volume |
Volume | 37 |
Issue number | 4 |
DOIs | |
Publication status | Published - 2012 May |
All Science Journal Classification (ASJC) codes