TY - JOUR
T1 - The effect of strand bias in Illumina short-read sequencing data
AU - Guo, Yan
AU - Li, Jiang
AU - Li, Chung I.
AU - Long, Jirong
AU - Samuels, David C.
AU - Shyr, Yu
N1 - Funding Information:
This work was partly supported by NIH grants R01HG004517 (JH, CL) and R01CA124558 and R01CA62477 (JL, JH, WZ, CL). Patient recruitment and sample collection was supported by R01CA64277. Sample preparation was conducted at the Survey and Biospecimen Core, which is supported in part by the Vanderbilt-Ingram Cancer Center (P30 CA68485). We also would like to thank Peggy Schuyler and Margot Bjoring for their editorial support.
PY - 2012/11/24
Y1 - 2012/11/24
N2 - Background: When using Illumina high throughput short read data, sometimes the genotype inferred from the positive strand and negative strand are significantly different, with one homozygous and the other heterozygous. This phenomenon is known as strand bias. In this study, we used Illumina short-read sequencing data to evaluate the effect of strand bias on genotyping quality, and to explore the possible causes of strand bias.Result: We collected 22 breast cancer samples from 22 patients and sequenced their exome using the Illumina GAIIx machine. By comparing the consistency between the genotypes inferred from this sequencing data with the genotypes inferred from SNP chip data, we found that, when using sequencing data, SNPs with extreme strand bias did not have significantly lower consistency rates compared to SNPs with low or no strand bias. However, this result may be limited by the small subset of SNPs present in both the exome sequencing and the SNP chip data. We further compared the transition and transversion ratio and the number of novel non-synonymous SNPs between the SNPs with low or no strand bias and those with extreme strand bias, and found that SNPs with low or no strand bias have better overall quality. We also discovered that the strand bias occurs randomly at genomic positions across these samples, and observed no consistent pattern of strand bias location across samples. By comparing results from two different aligners, BWA and Bowtie, we found very consistent strand bias patterns. Thus strand bias is unlikely to be caused by alignment artifacts. We successfully replicated our results using two additional independent datasets with different capturing methods and Illumina sequencers.Conclusion: Extreme strand bias indicates a potential high false-positive rate for SNPs.
AB - Background: When using Illumina high throughput short read data, sometimes the genotype inferred from the positive strand and negative strand are significantly different, with one homozygous and the other heterozygous. This phenomenon is known as strand bias. In this study, we used Illumina short-read sequencing data to evaluate the effect of strand bias on genotyping quality, and to explore the possible causes of strand bias.Result: We collected 22 breast cancer samples from 22 patients and sequenced their exome using the Illumina GAIIx machine. By comparing the consistency between the genotypes inferred from this sequencing data with the genotypes inferred from SNP chip data, we found that, when using sequencing data, SNPs with extreme strand bias did not have significantly lower consistency rates compared to SNPs with low or no strand bias. However, this result may be limited by the small subset of SNPs present in both the exome sequencing and the SNP chip data. We further compared the transition and transversion ratio and the number of novel non-synonymous SNPs between the SNPs with low or no strand bias and those with extreme strand bias, and found that SNPs with low or no strand bias have better overall quality. We also discovered that the strand bias occurs randomly at genomic positions across these samples, and observed no consistent pattern of strand bias location across samples. By comparing results from two different aligners, BWA and Bowtie, we found very consistent strand bias patterns. Thus strand bias is unlikely to be caused by alignment artifacts. We successfully replicated our results using two additional independent datasets with different capturing methods and Illumina sequencers.Conclusion: Extreme strand bias indicates a potential high false-positive rate for SNPs.
UR - http://www.scopus.com/inward/record.url?scp=84869876659&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84869876659&partnerID=8YFLogxK
U2 - 10.1186/1471-2164-13-666
DO - 10.1186/1471-2164-13-666
M3 - Article
C2 - 23176052
AN - SCOPUS:84869876659
SN - 1471-2164
VL - 13
JO - BMC genomics
JF - BMC genomics
IS - 1
M1 - 666