TY - JOUR
T1 - Transcatheter Closure of Patent Ductus Arteriosus in Premature Infants With Very Low Birth Weight
AU - Wang, Jieh Neng
AU - Lin, Yung Chieh
AU - Hsieh, Min Ling
AU - Wei, Yu Jen
AU - Ju, Ying Tzu
AU - Wu, Jing Ming
N1 - Publisher Copyright:
© Copyright © 2021 Wang, Lin, Hsieh, Wei, Ju and Wu.
PY - 2021/1/14
Y1 - 2021/1/14
N2 - Background: The aim of this study was to describe our experience with transcatheter device closure of patent ductus arteriosus (PDA) in symptomatic low-birth-weight premature infants. Methods: We performed a retrospective study of infants born with a birth body weight of < 2,000 g and admitted to National Cheng Kung University Hospital from September 2014 to December 2019. Basic demographic and clinical information as well as echocardiographic and angiographic data were recorded. Results: Twenty-five premature infants (11 boys and 14 girls) born at gestational ages ranging between 22 and 35 weeks (mean, 25 weeks) were identified. The mean age at procedure was 34.5 ± 5.5 days, and the mean weight was 1,209 ± 94 g (range, 478–1,980 g). The mean diameter of the PDA was 3.4 ± 0.2 mm (range, 2.0–5.4 mm). The following devices were used in this study: Amplatzer Ductal Occluder II additional size (n = 20), Amplatzer Vascular Plug I (n = 1), and Amplatzer Vascular Plug II (n = 4). Complete closure was achieved in all patients. The mean follow-up period was 30.1 ± 17.3 months (range, 6–68 months). In total, 3 patients had left pulmonary artery (LPA) stenosis and 1 patient had coarctation of the aorta during the follow-up period. Younger procedure age and smaller procedure body weight were significantly associated with these obstructions. Conclusions: Performing transcatheter PDA closure in symptomatic premature infants weighing more than 478 g is feasible using currently available devices; moreover, the procedure serves as an alternative to surgery.
AB - Background: The aim of this study was to describe our experience with transcatheter device closure of patent ductus arteriosus (PDA) in symptomatic low-birth-weight premature infants. Methods: We performed a retrospective study of infants born with a birth body weight of < 2,000 g and admitted to National Cheng Kung University Hospital from September 2014 to December 2019. Basic demographic and clinical information as well as echocardiographic and angiographic data were recorded. Results: Twenty-five premature infants (11 boys and 14 girls) born at gestational ages ranging between 22 and 35 weeks (mean, 25 weeks) were identified. The mean age at procedure was 34.5 ± 5.5 days, and the mean weight was 1,209 ± 94 g (range, 478–1,980 g). The mean diameter of the PDA was 3.4 ± 0.2 mm (range, 2.0–5.4 mm). The following devices were used in this study: Amplatzer Ductal Occluder II additional size (n = 20), Amplatzer Vascular Plug I (n = 1), and Amplatzer Vascular Plug II (n = 4). Complete closure was achieved in all patients. The mean follow-up period was 30.1 ± 17.3 months (range, 6–68 months). In total, 3 patients had left pulmonary artery (LPA) stenosis and 1 patient had coarctation of the aorta during the follow-up period. Younger procedure age and smaller procedure body weight were significantly associated with these obstructions. Conclusions: Performing transcatheter PDA closure in symptomatic premature infants weighing more than 478 g is feasible using currently available devices; moreover, the procedure serves as an alternative to surgery.
UR - http://www.scopus.com/inward/record.url?scp=85100090720&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85100090720&partnerID=8YFLogxK
U2 - 10.3389/fped.2020.615919
DO - 10.3389/fped.2020.615919
M3 - Article
AN - SCOPUS:85100090720
SN - 2296-2360
VL - 8
JO - Frontiers in Pediatrics
JF - Frontiers in Pediatrics
M1 - 615919
ER -