TY - JOUR
T1 - Video-based gait analysis for functional evaluation of healing achilles tendon in rats.
AU - Liang, Jen I.
AU - Chen, Meng Yi
AU - Hsieh, Tsung Hsun
AU - Liu, Chih Yu
AU - Lam, Chen Fuh
AU - Chen, Jia-Jin
AU - Yeh, Ming-Long
PY - 2012/1/1
Y1 - 2012/1/1
N2 - Video-based walking track systems have been developed for gait analysis in rat models. However, there is no previous study using video-based tracking systems to address the gait parameters to evaluate the recovery of Achilles tendon rupture models. This study conducted a comprehensive gait analysis using a video-based image processing system. Eighteen Sprague-Dawley rats were randomly assigned to one of three interventional conditions: sham surgery, Achilles tendon repair, and Achilles tendon defect. After surgery, all animals were evaluated using a video-based walking track system. The gait parameters and the Achilles functional index (AFI) were further analyzed. The ankle joint angles of the injury side at mid-stance and pre-swing were highly correlated with the AFI. However, lack of sensitivity was found for the AFI. Increased measurement sensitivity of the Achilles tendon healing condition was found in the ankle joint angle of the involved side at the pre-swing and the level of asymmetry of the hindlimb joint position and stance/swing time. The overall sensitivity of the ankle motion analysis was significantly higher than that of AFI. We conclude that the ankle motion analysis is a reliable, reproducible, and sensitive tool for Achilles tendon analysis in rats.
AB - Video-based walking track systems have been developed for gait analysis in rat models. However, there is no previous study using video-based tracking systems to address the gait parameters to evaluate the recovery of Achilles tendon rupture models. This study conducted a comprehensive gait analysis using a video-based image processing system. Eighteen Sprague-Dawley rats were randomly assigned to one of three interventional conditions: sham surgery, Achilles tendon repair, and Achilles tendon defect. After surgery, all animals were evaluated using a video-based walking track system. The gait parameters and the Achilles functional index (AFI) were further analyzed. The ankle joint angles of the injury side at mid-stance and pre-swing were highly correlated with the AFI. However, lack of sensitivity was found for the AFI. Increased measurement sensitivity of the Achilles tendon healing condition was found in the ankle joint angle of the involved side at the pre-swing and the level of asymmetry of the hindlimb joint position and stance/swing time. The overall sensitivity of the ankle motion analysis was significantly higher than that of AFI. We conclude that the ankle motion analysis is a reliable, reproducible, and sensitive tool for Achilles tendon analysis in rats.
UR - http://www.scopus.com/inward/record.url?scp=85027931051&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85027931051&partnerID=8YFLogxK
M3 - Article
C2 - 22810838
AN - SCOPUS:85027931051
VL - 40
SP - 2532
EP - 2540
JO - Annals of Biomedical Engineering
JF - Annals of Biomedical Engineering
SN - 0090-6964
IS - 12
ER -