TY - GEN
T1 - 3D-3D Registration of partial capitate bones using spin-images
AU - Breighner, Ryan
AU - Holmes, David R.
AU - Leng, Shuai
AU - An, Kai Nan
AU - McCollough, Cynthia
AU - Zhao, Kristin
PY - 2013
Y1 - 2013
N2 - It is often necessary to register partial objects in medical imaging. Due to limited field of view (FOV), the entirety of an object cannot always be imaged. This study presents a novel application of an existing registration algorithm to this problem. The spin-image algorithm [1] creates pose-invariant representations of global shape with respect to individual mesh vertices. These 'spin-images,' are then compared for two different poses of the same object to establish correspondences and subsequently determine relative orientation of the poses. In this study, the spin-image algorithm is applied to 4DCT-derived capitate bone surfaces to assess the relative accuracy of registration with various amounts of geometry excluded. The limited longitudinal coverage under the 4DCT technique (38.4mm, [2]), results in partial views of the capitate when imaging wrist motions. This study assesses the ability of the spin-image algorithm to register partial bone surfaces by artificially restricting the capitate geometry available for registration. Under IRB approval, standard static CT and 4DCT scans were obtained on a patient. The capitate was segmented from the static CT and one phase of 4DCT in which the whole bone was available. Spin-image registration was performed between the static and 4DCT. Distal portions of the 4DCT capitate (10-70%) were then progressively removed and registration was repeated. Registration accuracy was evaluated by angular errors and the percentage of sub-resolution fitting. It was determined that 60% of the distal capitate could be omitted without appreciable effect on registration accuracy using the spin-image algorithm (angular error < 1.5 degree, sub-resolution fitting > 98.4%).
AB - It is often necessary to register partial objects in medical imaging. Due to limited field of view (FOV), the entirety of an object cannot always be imaged. This study presents a novel application of an existing registration algorithm to this problem. The spin-image algorithm [1] creates pose-invariant representations of global shape with respect to individual mesh vertices. These 'spin-images,' are then compared for two different poses of the same object to establish correspondences and subsequently determine relative orientation of the poses. In this study, the spin-image algorithm is applied to 4DCT-derived capitate bone surfaces to assess the relative accuracy of registration with various amounts of geometry excluded. The limited longitudinal coverage under the 4DCT technique (38.4mm, [2]), results in partial views of the capitate when imaging wrist motions. This study assesses the ability of the spin-image algorithm to register partial bone surfaces by artificially restricting the capitate geometry available for registration. Under IRB approval, standard static CT and 4DCT scans were obtained on a patient. The capitate was segmented from the static CT and one phase of 4DCT in which the whole bone was available. Spin-image registration was performed between the static and 4DCT. Distal portions of the 4DCT capitate (10-70%) were then progressively removed and registration was repeated. Registration accuracy was evaluated by angular errors and the percentage of sub-resolution fitting. It was determined that 60% of the distal capitate could be omitted without appreciable effect on registration accuracy using the spin-image algorithm (angular error < 1.5 degree, sub-resolution fitting > 98.4%).
UR - http://www.scopus.com/inward/record.url?scp=84878565432&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84878565432&partnerID=8YFLogxK
U2 - 10.1117/12.2008685
DO - 10.1117/12.2008685
M3 - Conference contribution
AN - SCOPUS:84878565432
SN - 9780819494450
T3 - Proceedings of SPIE - The International Society for Optical Engineering
BT - Medical Imaging 2013
T2 - Medical Imaging 2013: Image-Guided Procedures, Robotic Interventions, and Modeling
Y2 - 12 February 2013 through 14 February 2013
ER -