A calculation for complex eye-blink duration by regression

Chin Shun Hsieh, Cheng-Chi Tai

研究成果: Paper

1 引文 (Scopus)

摘要

This paper proposes a calculation for complex eye-blink duration by regression. The eye-blink durations are similar to EOG (electro-oculogram or electro-oculography), Simple electrode pads are used as sensors to acquire the right eyelid EOG signal and remove the artificial pseudo-signal. A realtime microcontroller calculates and displays the blink-durations and number of blinks. According to measurement results, the calculations of the numbers of blinks can reach high accuracy. The accuracy of blink duration determination is close to 95% via a 1 kHz sampling rate. In addition, the proposed detection system has advantages on low cost and low power consumption.

原文English
頁面549-552
頁數4
DOIs
出版狀態Published - 2013 五月 27
事件2013 IEEE International Symposium on Next-Generation Electronics, ISNE 2013 - Kaohsiung, Taiwan
持續時間: 2013 二月 252013 二月 26

Other

Other2013 IEEE International Symposium on Next-Generation Electronics, ISNE 2013
國家Taiwan
城市Kaohsiung
期間13-02-2513-02-26

指紋

Microcontrollers
Electric power utilization
Sampling
Electrodes
Sensors
Costs

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering

引用此文

Hsieh, C. S., & Tai, C-C. (2013). A calculation for complex eye-blink duration by regression. 549-552. 論文發表於 2013 IEEE International Symposium on Next-Generation Electronics, ISNE 2013, Kaohsiung, Taiwan. https://doi.org/10.1109/ISNE.2013.6512420
Hsieh, Chin Shun ; Tai, Cheng-Chi. / A calculation for complex eye-blink duration by regression. 論文發表於 2013 IEEE International Symposium on Next-Generation Electronics, ISNE 2013, Kaohsiung, Taiwan.4 p.
@conference{acfc7e05f7c74bf28eb19758504e7e02,
title = "A calculation for complex eye-blink duration by regression",
abstract = "This paper proposes a calculation for complex eye-blink duration by regression. The eye-blink durations are similar to EOG (electro-oculogram or electro-oculography), Simple electrode pads are used as sensors to acquire the right eyelid EOG signal and remove the artificial pseudo-signal. A realtime microcontroller calculates and displays the blink-durations and number of blinks. According to measurement results, the calculations of the numbers of blinks can reach high accuracy. The accuracy of blink duration determination is close to 95{\%} via a 1 kHz sampling rate. In addition, the proposed detection system has advantages on low cost and low power consumption.",
author = "Hsieh, {Chin Shun} and Cheng-Chi Tai",
year = "2013",
month = "5",
day = "27",
doi = "10.1109/ISNE.2013.6512420",
language = "English",
pages = "549--552",
note = "2013 IEEE International Symposium on Next-Generation Electronics, ISNE 2013 ; Conference date: 25-02-2013 Through 26-02-2013",

}

Hsieh, CS & Tai, C-C 2013, 'A calculation for complex eye-blink duration by regression' 論文發表於 2013 IEEE International Symposium on Next-Generation Electronics, ISNE 2013, Kaohsiung, Taiwan, 13-02-25 - 13-02-26, 頁 549-552. https://doi.org/10.1109/ISNE.2013.6512420

A calculation for complex eye-blink duration by regression. / Hsieh, Chin Shun; Tai, Cheng-Chi.

2013. 549-552 論文發表於 2013 IEEE International Symposium on Next-Generation Electronics, ISNE 2013, Kaohsiung, Taiwan.

研究成果: Paper

TY - CONF

T1 - A calculation for complex eye-blink duration by regression

AU - Hsieh, Chin Shun

AU - Tai, Cheng-Chi

PY - 2013/5/27

Y1 - 2013/5/27

N2 - This paper proposes a calculation for complex eye-blink duration by regression. The eye-blink durations are similar to EOG (electro-oculogram or electro-oculography), Simple electrode pads are used as sensors to acquire the right eyelid EOG signal and remove the artificial pseudo-signal. A realtime microcontroller calculates and displays the blink-durations and number of blinks. According to measurement results, the calculations of the numbers of blinks can reach high accuracy. The accuracy of blink duration determination is close to 95% via a 1 kHz sampling rate. In addition, the proposed detection system has advantages on low cost and low power consumption.

AB - This paper proposes a calculation for complex eye-blink duration by regression. The eye-blink durations are similar to EOG (electro-oculogram or electro-oculography), Simple electrode pads are used as sensors to acquire the right eyelid EOG signal and remove the artificial pseudo-signal. A realtime microcontroller calculates and displays the blink-durations and number of blinks. According to measurement results, the calculations of the numbers of blinks can reach high accuracy. The accuracy of blink duration determination is close to 95% via a 1 kHz sampling rate. In addition, the proposed detection system has advantages on low cost and low power consumption.

UR - http://www.scopus.com/inward/record.url?scp=84877950140&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84877950140&partnerID=8YFLogxK

U2 - 10.1109/ISNE.2013.6512420

DO - 10.1109/ISNE.2013.6512420

M3 - Paper

AN - SCOPUS:84877950140

SP - 549

EP - 552

ER -

Hsieh CS, Tai C-C. A calculation for complex eye-blink duration by regression. 2013. 論文發表於 2013 IEEE International Symposium on Next-Generation Electronics, ISNE 2013, Kaohsiung, Taiwan. https://doi.org/10.1109/ISNE.2013.6512420