TY - JOUR
T1 - A compact circular heterodyne interferometer for simultaneous measurements of variation in the magnitude of phase retardation and principal axis angle
AU - Lee, S. Y.
AU - Lin, J. F.
AU - Lo, Y. L.
PY - 2004/5
Y1 - 2004/5
N2 - This paper presents a compact configuration for simultaneous measurements of variation in the magnitude of phase retardation and principal axis angle in optical materials. The configuration comprises a circular heterodyne common-path interferometer, in which a sawtooth voltage waveform is used to regulate an electro-optic (EO) modulator. Changes in phase retardation and in the angle of the principal axis are demodulated by a lock-in amplifier via a simple signal-processing algorithm. Compared to the conventional configurations, the proposed interferometer offers an easier setup, has only one detection channel, and employs a simpler signal-processing operation. The validity of the proposed measurement system is demonstrated using a quarter-wave plate as a sample. The results indicate that the average absolute errors of the phase retardation and principal axis angle of quarter-wave plate are 4.88% and 0.94°, respectively. Furthermore, the root-mean-square resolutions of the magnitude of phase retardation and the principal axis angle are shown to be 1.59° and 0.10°, respectively. The dynamic range of phase retardation measurement is up to 90° and that of the principal axis angle measurement is up to 180°.
AB - This paper presents a compact configuration for simultaneous measurements of variation in the magnitude of phase retardation and principal axis angle in optical materials. The configuration comprises a circular heterodyne common-path interferometer, in which a sawtooth voltage waveform is used to regulate an electro-optic (EO) modulator. Changes in phase retardation and in the angle of the principal axis are demodulated by a lock-in amplifier via a simple signal-processing algorithm. Compared to the conventional configurations, the proposed interferometer offers an easier setup, has only one detection channel, and employs a simpler signal-processing operation. The validity of the proposed measurement system is demonstrated using a quarter-wave plate as a sample. The results indicate that the average absolute errors of the phase retardation and principal axis angle of quarter-wave plate are 4.88% and 0.94°, respectively. Furthermore, the root-mean-square resolutions of the magnitude of phase retardation and the principal axis angle are shown to be 1.59° and 0.10°, respectively. The dynamic range of phase retardation measurement is up to 90° and that of the principal axis angle measurement is up to 180°.
UR - http://www.scopus.com/inward/record.url?scp=2542476958&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=2542476958&partnerID=8YFLogxK
U2 - 10.1088/0957-0233/15/5/029
DO - 10.1088/0957-0233/15/5/029
M3 - Article
AN - SCOPUS:2542476958
SN - 0957-0233
VL - 15
SP - 978
EP - 982
JO - Measurement Science and Technology
JF - Measurement Science and Technology
IS - 5
ER -