A CT-guided fat transversing coaxial biopsy technique for pancreatic lesion biopsy that avoids major organs and vessels

研究成果: Article

1 引文 (Scopus)

摘要

Background/Aims: The purpose of this study is to report our results using a computed tomography (CT)-guided fat transversing coaxial biopsy technique for pancreatic lesion biopsy that avoids major organs and vessels. We retrospectively reviewed the records of patients referred to our department for pancreatic mass biopsy. Patients and Methods: The records of patients (from June 2008 to August 2014) in whom biopsy was performed under CT guidance with a coaxial needle using a fat transversing technique were reviewed. Patient demographic data and biopsy outcomes were collected. We aimed to compare differences between lesion size and biopsy outcome, the independent two-samples t-Test was used. Results: A total of 122 patients who underwent 17-G coaxial needle biopsy were included. The mean pancreatic lesion size was 3.2 cm, and in 30 patients it was more than 4 cm. The majority of lesions were located in the head of the pancreas (44.3%). No transorgan biopsies were performed. In most patients, the biopsy was performed via a fat traversing detour route (93.4%), and a successful diagnosis was made based on the biopsy outcome in 96.7% patients. Complications occurred in five patients (4.1%); three of the patients developed a fever, and two developed pancreatitis. All patients recovered with symptomatic treatment. Conclusion: CT-guided coaxial core biopsy of pancreatic lesions using a fat detour route appears to be a safe and effective method for obtaining pancreatic lesion biopsies with a high success rate and low complication rate.

原文English
頁(從 - 到)341-347
頁數7
期刊Saudi Journal of Gastroenterology
23
發行號6
DOIs
出版狀態Published - 2017 十一月 1

指紋

Fats
Tomography
Biopsy
Needle Biopsy
Pancreatitis
Needles
Pancreas
Fever
Demography

All Science Journal Classification (ASJC) codes

  • Gastroenterology

引用此文

@article{74b42455201345bd9c287e86efb0d49d,
title = "A CT-guided fat transversing coaxial biopsy technique for pancreatic lesion biopsy that avoids major organs and vessels",
abstract = "Background/Aims: The purpose of this study is to report our results using a computed tomography (CT)-guided fat transversing coaxial biopsy technique for pancreatic lesion biopsy that avoids major organs and vessels. We retrospectively reviewed the records of patients referred to our department for pancreatic mass biopsy. Patients and Methods: The records of patients (from June 2008 to August 2014) in whom biopsy was performed under CT guidance with a coaxial needle using a fat transversing technique were reviewed. Patient demographic data and biopsy outcomes were collected. We aimed to compare differences between lesion size and biopsy outcome, the independent two-samples t-Test was used. Results: A total of 122 patients who underwent 17-G coaxial needle biopsy were included. The mean pancreatic lesion size was 3.2 cm, and in 30 patients it was more than 4 cm. The majority of lesions were located in the head of the pancreas (44.3{\%}). No transorgan biopsies were performed. In most patients, the biopsy was performed via a fat traversing detour route (93.4{\%}), and a successful diagnosis was made based on the biopsy outcome in 96.7{\%} patients. Complications occurred in five patients (4.1{\%}); three of the patients developed a fever, and two developed pancreatitis. All patients recovered with symptomatic treatment. Conclusion: CT-guided coaxial core biopsy of pancreatic lesions using a fat detour route appears to be a safe and effective method for obtaining pancreatic lesion biopsies with a high success rate and low complication rate.",
author = "Lin, {Chia Ying} and Ou, {Ming Ching} and Liu, {Yi Sheng} and Chuang, {Ming Tsung} and Shan, {Yan Shen} and Tsai, {Hong Ming} and Wang, {Chien Kuo} and Tsai, {Yi Shan}",
year = "2017",
month = "11",
day = "1",
doi = "10.4103/sjg.SJG_199_17",
language = "English",
volume = "23",
pages = "341--347",
journal = "Saudi Journal of Gastroenterology",
issn = "1319-3767",
publisher = "Medknow Publications and Media Pvt. Ltd",
number = "6",

}

TY - JOUR

T1 - A CT-guided fat transversing coaxial biopsy technique for pancreatic lesion biopsy that avoids major organs and vessels

AU - Lin, Chia Ying

AU - Ou, Ming Ching

AU - Liu, Yi Sheng

AU - Chuang, Ming Tsung

AU - Shan, Yan Shen

AU - Tsai, Hong Ming

AU - Wang, Chien Kuo

AU - Tsai, Yi Shan

PY - 2017/11/1

Y1 - 2017/11/1

N2 - Background/Aims: The purpose of this study is to report our results using a computed tomography (CT)-guided fat transversing coaxial biopsy technique for pancreatic lesion biopsy that avoids major organs and vessels. We retrospectively reviewed the records of patients referred to our department for pancreatic mass biopsy. Patients and Methods: The records of patients (from June 2008 to August 2014) in whom biopsy was performed under CT guidance with a coaxial needle using a fat transversing technique were reviewed. Patient demographic data and biopsy outcomes were collected. We aimed to compare differences between lesion size and biopsy outcome, the independent two-samples t-Test was used. Results: A total of 122 patients who underwent 17-G coaxial needle biopsy were included. The mean pancreatic lesion size was 3.2 cm, and in 30 patients it was more than 4 cm. The majority of lesions were located in the head of the pancreas (44.3%). No transorgan biopsies were performed. In most patients, the biopsy was performed via a fat traversing detour route (93.4%), and a successful diagnosis was made based on the biopsy outcome in 96.7% patients. Complications occurred in five patients (4.1%); three of the patients developed a fever, and two developed pancreatitis. All patients recovered with symptomatic treatment. Conclusion: CT-guided coaxial core biopsy of pancreatic lesions using a fat detour route appears to be a safe and effective method for obtaining pancreatic lesion biopsies with a high success rate and low complication rate.

AB - Background/Aims: The purpose of this study is to report our results using a computed tomography (CT)-guided fat transversing coaxial biopsy technique for pancreatic lesion biopsy that avoids major organs and vessels. We retrospectively reviewed the records of patients referred to our department for pancreatic mass biopsy. Patients and Methods: The records of patients (from June 2008 to August 2014) in whom biopsy was performed under CT guidance with a coaxial needle using a fat transversing technique were reviewed. Patient demographic data and biopsy outcomes were collected. We aimed to compare differences between lesion size and biopsy outcome, the independent two-samples t-Test was used. Results: A total of 122 patients who underwent 17-G coaxial needle biopsy were included. The mean pancreatic lesion size was 3.2 cm, and in 30 patients it was more than 4 cm. The majority of lesions were located in the head of the pancreas (44.3%). No transorgan biopsies were performed. In most patients, the biopsy was performed via a fat traversing detour route (93.4%), and a successful diagnosis was made based on the biopsy outcome in 96.7% patients. Complications occurred in five patients (4.1%); three of the patients developed a fever, and two developed pancreatitis. All patients recovered with symptomatic treatment. Conclusion: CT-guided coaxial core biopsy of pancreatic lesions using a fat detour route appears to be a safe and effective method for obtaining pancreatic lesion biopsies with a high success rate and low complication rate.

UR - http://www.scopus.com/inward/record.url?scp=85038363404&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85038363404&partnerID=8YFLogxK

U2 - 10.4103/sjg.SJG_199_17

DO - 10.4103/sjg.SJG_199_17

M3 - Article

C2 - 29205187

AN - SCOPUS:85038363404

VL - 23

SP - 341

EP - 347

JO - Saudi Journal of Gastroenterology

JF - Saudi Journal of Gastroenterology

SN - 1319-3767

IS - 6

ER -