TY - JOUR
T1 - A hybrid strategy to integrate surface-based and mutual-information-based methods for co-registering brain SPECT and MR images
AU - Liao, Yuan Lin
AU - Sun, Yung Nien
AU - Guo, Wan Yuo
AU - Chou, Yuan Hwa
AU - Hsieh, Jen Chuen
AU - Wu, Yu Te
N1 - Funding Information:
Acknowledgments The authors express gratitude to Dr. Berengere Aubert-Broche for providing a series of synthetic images, and Shih-Pei Chen for his help on data acquisition and comments. Our gratitude also goes to Jaya Ramchandani for his assistance in English language editing. This study was partially supported by the Taipei Veterans General Hospital (V96 ER1-005), and the National Science Council of Taiwan (NSC 95-2752-B-075-001-PAE, NSC 95-2752-B-010-006-PAE, NSC 96-2752-B-075-001-PAE, NSC 96-2752-B-010-006-PAE, NSC 97-2752-B-075-001-PAE, NSC 97-2752-B-010-001-PAE, NSC 98-2752-B-075-001-PAE, and NSC 98-2752-B-010-001-PAE).
PY - 2011/6
Y1 - 2011/6
N2 - Co-registration of brain SPECT and MR images has been used extensively in clinical applications. The complementary features of two major co-registration methods-surface- and mutual-information-based (MI-based)-motivated us to study a hybrid-based scheme that uses the surface-based method to achieve a quick alignment, followed by the MI-based method for fine tuning. Computer simulations were conducted to evaluate the accuracy and robustness of surface-, MI-, and hybrid-based registration methods by designing different levels of noise and mismatch in the registration experiments. Results demonstrated that the hybrid surface-MI-based scheme outperforms both the surface- and MI-based methods in providing superior accuracy and success rates. Specifically, the translational and rotational errors were no more than 1 mm and 2°, respectively, with consistent success rates over 98%. Besides, the hybrid-based method saved 12-53% of the computation efforts, compared with using the MI-based method alone. We recommend the use of hybrid-based method when the orientational differences between the floating and reference images exceed 10°.
AB - Co-registration of brain SPECT and MR images has been used extensively in clinical applications. The complementary features of two major co-registration methods-surface- and mutual-information-based (MI-based)-motivated us to study a hybrid-based scheme that uses the surface-based method to achieve a quick alignment, followed by the MI-based method for fine tuning. Computer simulations were conducted to evaluate the accuracy and robustness of surface-, MI-, and hybrid-based registration methods by designing different levels of noise and mismatch in the registration experiments. Results demonstrated that the hybrid surface-MI-based scheme outperforms both the surface- and MI-based methods in providing superior accuracy and success rates. Specifically, the translational and rotational errors were no more than 1 mm and 2°, respectively, with consistent success rates over 98%. Besides, the hybrid-based method saved 12-53% of the computation efforts, compared with using the MI-based method alone. We recommend the use of hybrid-based method when the orientational differences between the floating and reference images exceed 10°.
UR - http://www.scopus.com/inward/record.url?scp=79959882643&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79959882643&partnerID=8YFLogxK
U2 - 10.1007/s11517-010-0724-9
DO - 10.1007/s11517-010-0724-9
M3 - Article
C2 - 21191661
AN - SCOPUS:79959882643
SN - 0140-0118
VL - 49
SP - 671
EP - 685
JO - Medical and Biological Engineering and Computing
JF - Medical and Biological Engineering and Computing
IS - 6
ER -