A new dual channel pulse wave velocity measurement system

Yung Kang Chen, Hsien Tsai Wu, Chih Kai Chi, Wei Chuan Tsai, Ju Yi Chen, Ming Chun Wang

研究成果: Conference contribution

13 引文 (Scopus)

摘要

Pulse wave velocity (PWV) is the most popular index to assessment the arterial stiffness. Currently, several non-invasive examination methods with single channel for PWV are announced. This paper proposes a non-invasive digital volume pulse (DVP) measuring system using a dual channel simultaneous measurement method try to meet the demands for home healthcare equipment which is easy to operate. Through synchronal technical in measuring DVP signals from finger and toe can achieves more precise time and substantially reduces the time spend in measurement procedures. In the other side, the proposed system developed an algorithm to locate the "Foot of the wave" without facilitating of electrocardiogram (ECG).

原文English
主出版物標題Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004
頁面17-21
頁數5
DOIs
出版狀態Published - 2004 九月 24
事件Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004 - Taichung, Taiwan
持續時間: 2004 五月 192004 五月 21

出版系列

名字Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004

Other

OtherProceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004
國家Taiwan
城市Taichung
期間04-05-1904-05-21

指紋

Velocity measurement
Electrocardiography
Stiffness

All Science Journal Classification (ASJC) codes

  • Engineering(all)

引用此文

Chen, Y. K., Wu, H. T., Chi, C. K., Tsai, W. C., Chen, J. Y., & Wang, M. C. (2004). A new dual channel pulse wave velocity measurement system. 於 Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004 (頁 17-21). (Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004). https://doi.org/10.1016/S0030-5898(03)00052-X
Chen, Yung Kang ; Wu, Hsien Tsai ; Chi, Chih Kai ; Tsai, Wei Chuan ; Chen, Ju Yi ; Wang, Ming Chun. / A new dual channel pulse wave velocity measurement system. Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004. 2004. 頁 17-21 (Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004).
@inproceedings{5ac030ec6e754255ae15db872dbf03d7,
title = "A new dual channel pulse wave velocity measurement system",
abstract = "Pulse wave velocity (PWV) is the most popular index to assessment the arterial stiffness. Currently, several non-invasive examination methods with single channel for PWV are announced. This paper proposes a non-invasive digital volume pulse (DVP) measuring system using a dual channel simultaneous measurement method try to meet the demands for home healthcare equipment which is easy to operate. Through synchronal technical in measuring DVP signals from finger and toe can achieves more precise time and substantially reduces the time spend in measurement procedures. In the other side, the proposed system developed an algorithm to locate the {"}Foot of the wave{"} without facilitating of electrocardiogram (ECG).",
author = "Chen, {Yung Kang} and Wu, {Hsien Tsai} and Chi, {Chih Kai} and Tsai, {Wei Chuan} and Chen, {Ju Yi} and Wang, {Ming Chun}",
year = "2004",
month = "9",
day = "24",
doi = "10.1016/S0030-5898(03)00052-X",
language = "English",
isbn = "0769521738",
series = "Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004",
pages = "17--21",
booktitle = "Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004",

}

Chen, YK, Wu, HT, Chi, CK, Tsai, WC, Chen, JY & Wang, MC 2004, A new dual channel pulse wave velocity measurement system. 於 Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004. Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004, 頁 17-21, Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004, Taichung, Taiwan, 04-05-19. https://doi.org/10.1016/S0030-5898(03)00052-X

A new dual channel pulse wave velocity measurement system. / Chen, Yung Kang; Wu, Hsien Tsai; Chi, Chih Kai; Tsai, Wei Chuan; Chen, Ju Yi; Wang, Ming Chun.

Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004. 2004. p. 17-21 (Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004).

研究成果: Conference contribution

TY - GEN

T1 - A new dual channel pulse wave velocity measurement system

AU - Chen, Yung Kang

AU - Wu, Hsien Tsai

AU - Chi, Chih Kai

AU - Tsai, Wei Chuan

AU - Chen, Ju Yi

AU - Wang, Ming Chun

PY - 2004/9/24

Y1 - 2004/9/24

N2 - Pulse wave velocity (PWV) is the most popular index to assessment the arterial stiffness. Currently, several non-invasive examination methods with single channel for PWV are announced. This paper proposes a non-invasive digital volume pulse (DVP) measuring system using a dual channel simultaneous measurement method try to meet the demands for home healthcare equipment which is easy to operate. Through synchronal technical in measuring DVP signals from finger and toe can achieves more precise time and substantially reduces the time spend in measurement procedures. In the other side, the proposed system developed an algorithm to locate the "Foot of the wave" without facilitating of electrocardiogram (ECG).

AB - Pulse wave velocity (PWV) is the most popular index to assessment the arterial stiffness. Currently, several non-invasive examination methods with single channel for PWV are announced. This paper proposes a non-invasive digital volume pulse (DVP) measuring system using a dual channel simultaneous measurement method try to meet the demands for home healthcare equipment which is easy to operate. Through synchronal technical in measuring DVP signals from finger and toe can achieves more precise time and substantially reduces the time spend in measurement procedures. In the other side, the proposed system developed an algorithm to locate the "Foot of the wave" without facilitating of electrocardiogram (ECG).

UR - http://www.scopus.com/inward/record.url?scp=4544308347&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=4544308347&partnerID=8YFLogxK

U2 - 10.1016/S0030-5898(03)00052-X

DO - 10.1016/S0030-5898(03)00052-X

M3 - Conference contribution

AN - SCOPUS:4544308347

SN - 0769521738

SN - 9780769521732

T3 - Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004

SP - 17

EP - 21

BT - Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004

ER -

Chen YK, Wu HT, Chi CK, Tsai WC, Chen JY, Wang MC. A new dual channel pulse wave velocity measurement system. 於 Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004. 2004. p. 17-21. (Proceedings - Fourth IEEE Symposium on Bioinformatics and Bioengineering, BIBE 2004). https://doi.org/10.1016/S0030-5898(03)00052-X