TY - JOUR
T1 - A novel method of C1-C2 transarticular screw insertion for symptomatic atlantoaxial instability using a customized guiding block
T2 - A case report and a technical note
AU - Huang, Kuo Yuan
AU - Lin, Ruey Mo
AU - Fang, Jing Jing
N1 - Publisher Copyright:
© Copyright 2016 the Author(s). Published by Wolters Kluwer Health, Inc. All rights reserved.
PY - 2016
Y1 - 2016
N2 - Atlantoaxial instability treated with the C1-2 transarticular screw fixation is biomechanically more stable; however, the technique demanding and the potential risk of neurovascular injury create difficulties for clinical usage, and there is still lack of clinical experience till now. We reported an adult female patient with symptomatic atlantoaxial instability due to rheumatoid arthritis that was successfully treated with a bilateral C1-C2 transarticular screw fixation using a customized guiding block. We preoperatively determined the trajectories for bilateral C1-C2 transarticular screws on a 3-dimensional reconstruction model from the computed tomography (CT) and self-developed computer software, and designed a rapid prototyping customized guiding block in order to offer a guide for the entry point and insertion angle of the C1-C2 transarticular screws. The clinical outcome was good, and the follow-up period was >3 years. The accuracy of the screws is good in comparison with preoperative and postoperative CT findings, and no neurovascular injury occurred. The patient was accurately and successfully treated with a bilateral C1-C2 transarticular screw fixation using a customized guiding block.
AB - Atlantoaxial instability treated with the C1-2 transarticular screw fixation is biomechanically more stable; however, the technique demanding and the potential risk of neurovascular injury create difficulties for clinical usage, and there is still lack of clinical experience till now. We reported an adult female patient with symptomatic atlantoaxial instability due to rheumatoid arthritis that was successfully treated with a bilateral C1-C2 transarticular screw fixation using a customized guiding block. We preoperatively determined the trajectories for bilateral C1-C2 transarticular screws on a 3-dimensional reconstruction model from the computed tomography (CT) and self-developed computer software, and designed a rapid prototyping customized guiding block in order to offer a guide for the entry point and insertion angle of the C1-C2 transarticular screws. The clinical outcome was good, and the follow-up period was >3 years. The accuracy of the screws is good in comparison with preoperative and postoperative CT findings, and no neurovascular injury occurred. The patient was accurately and successfully treated with a bilateral C1-C2 transarticular screw fixation using a customized guiding block.
UR - http://www.scopus.com/inward/record.url?scp=84995945071&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84995945071&partnerID=8YFLogxK
U2 - 10.1097/MD.0000000000005100
DO - 10.1097/MD.0000000000005100
M3 - Article
C2 - 27787362
AN - SCOPUS:84995945071
SN - 0025-7974
VL - 95
JO - Medicine (United States)
JF - Medicine (United States)
IS - 43
M1 - e5100
ER -