A rare complication of ipsilateral femoral neck fracture after removal of the long Gamma nail in a healed intertrochanteric fracture

Chin Kai Huang, Chih Kai Hong, Wei Ren Su, Yi Hung Huang, Lin Yu Chao

研究成果: Article同行評審

2 引文 斯高帕斯(Scopus)

摘要

Ipsilateral femoral neck fracture after hardware removal in healed trochanteric fracture is a rare complication. We reported a case of a 79-year-old woman who had undergone open reduction and internal fixation for her left intertrochanteric fracture with a long Gamma nail about 1 year ago. She asked for implants removal due to local irritation. However, 5 days after implants removal, left subcapital femoral neck fracture occurred. Removal of implants under elective indications could lead to high complication rate. Orthopedic surgeons should perform the removal of hardware in healed intertrochanteric fracture for very selected cases.

原文English
頁(從 - 到)88-90