Absolute calibration of space- and time-resolving flat-field vacuum ultraviolet spectrograph under both P and S polarized light conditions for plasma diagnostics

Y. Okamoto, M. Yoshikawa, N. Yamaguchi, C. Watabe, T. Tamano, E. Kawamori, Y. Watanabe, T. Furukawa, Y. Kubota, K. Sedo, K. Yatsu

研究成果: Article

5 引文 (Scopus)

摘要

Measurement of spectra in the wavelength range from vacuum ultraviolet (VUV) to soft x ray is an important means to diagnose impurity behavior in magnetically confined plasmas used in fusion plasmas. Recently, a space- and time-resolving flat-field grazing-incidence VUV spectrograph was constructed for the simultaneous observation of spatial, temporal, and spectral distributions of plasma radiation in the wavelength range of 150-1050 Å. Absolute calibration experiments were performed at beamline 11C and beamline 12A in the Photon Factory at the High Energy Acceleration Research Organization. The absolute sensitivity of the VUV spectrograph was measured under both P and S polarized light conditions.

原文English
頁(從 - 到)4366-4371
頁數6
期刊Review of Scientific Instruments
72
發行號12
DOIs
出版狀態Published - 2001 十二月 1

指紋

Ultraviolet spectrographs
ultraviolet spectrometers
Plasma diagnostics
plasma diagnostics
Light polarization
polarized light
Calibration
Vacuum
Plasmas
vacuum
plasma radiation
Wavelength
temporal distribution
grazing incidence
industrial plants
wavelengths
Industrial plants
spatial distribution
Fusion reactions
Photons

All Science Journal Classification (ASJC) codes

  • Instrumentation

引用此文

Okamoto, Y. ; Yoshikawa, M. ; Yamaguchi, N. ; Watabe, C. ; Tamano, T. ; Kawamori, E. ; Watanabe, Y. ; Furukawa, T. ; Kubota, Y. ; Sedo, K. ; Yatsu, K. / Absolute calibration of space- and time-resolving flat-field vacuum ultraviolet spectrograph under both P and S polarized light conditions for plasma diagnostics. 於: Review of Scientific Instruments. 2001 ; 卷 72, 編號 12. 頁 4366-4371.
@article{2eb375db7d0847e8be7342b5a9888e37,
title = "Absolute calibration of space- and time-resolving flat-field vacuum ultraviolet spectrograph under both P and S polarized light conditions for plasma diagnostics",
abstract = "Measurement of spectra in the wavelength range from vacuum ultraviolet (VUV) to soft x ray is an important means to diagnose impurity behavior in magnetically confined plasmas used in fusion plasmas. Recently, a space- and time-resolving flat-field grazing-incidence VUV spectrograph was constructed for the simultaneous observation of spatial, temporal, and spectral distributions of plasma radiation in the wavelength range of 150-1050 {\AA}. Absolute calibration experiments were performed at beamline 11C and beamline 12A in the Photon Factory at the High Energy Acceleration Research Organization. The absolute sensitivity of the VUV spectrograph was measured under both P and S polarized light conditions.",
author = "Y. Okamoto and M. Yoshikawa and N. Yamaguchi and C. Watabe and T. Tamano and E. Kawamori and Y. Watanabe and T. Furukawa and Y. Kubota and K. Sedo and K. Yatsu",
year = "2001",
month = "12",
day = "1",
doi = "10.1063/1.1416105",
language = "English",
volume = "72",
pages = "4366--4371",
journal = "Review of Scientific Instruments",
issn = "0034-6748",
publisher = "American Institute of Physics Publising LLC",
number = "12",

}

Okamoto, Y, Yoshikawa, M, Yamaguchi, N, Watabe, C, Tamano, T, Kawamori, E, Watanabe, Y, Furukawa, T, Kubota, Y, Sedo, K & Yatsu, K 2001, 'Absolute calibration of space- and time-resolving flat-field vacuum ultraviolet spectrograph under both P and S polarized light conditions for plasma diagnostics', Review of Scientific Instruments, 卷 72, 編號 12, 頁 4366-4371. https://doi.org/10.1063/1.1416105

Absolute calibration of space- and time-resolving flat-field vacuum ultraviolet spectrograph under both P and S polarized light conditions for plasma diagnostics. / Okamoto, Y.; Yoshikawa, M.; Yamaguchi, N.; Watabe, C.; Tamano, T.; Kawamori, E.; Watanabe, Y.; Furukawa, T.; Kubota, Y.; Sedo, K.; Yatsu, K.

於: Review of Scientific Instruments, 卷 72, 編號 12, 01.12.2001, p. 4366-4371.

研究成果: Article

TY - JOUR

T1 - Absolute calibration of space- and time-resolving flat-field vacuum ultraviolet spectrograph under both P and S polarized light conditions for plasma diagnostics

AU - Okamoto, Y.

AU - Yoshikawa, M.

AU - Yamaguchi, N.

AU - Watabe, C.

AU - Tamano, T.

AU - Kawamori, E.

AU - Watanabe, Y.

AU - Furukawa, T.

AU - Kubota, Y.

AU - Sedo, K.

AU - Yatsu, K.

PY - 2001/12/1

Y1 - 2001/12/1

N2 - Measurement of spectra in the wavelength range from vacuum ultraviolet (VUV) to soft x ray is an important means to diagnose impurity behavior in magnetically confined plasmas used in fusion plasmas. Recently, a space- and time-resolving flat-field grazing-incidence VUV spectrograph was constructed for the simultaneous observation of spatial, temporal, and spectral distributions of plasma radiation in the wavelength range of 150-1050 Å. Absolute calibration experiments were performed at beamline 11C and beamline 12A in the Photon Factory at the High Energy Acceleration Research Organization. The absolute sensitivity of the VUV spectrograph was measured under both P and S polarized light conditions.

AB - Measurement of spectra in the wavelength range from vacuum ultraviolet (VUV) to soft x ray is an important means to diagnose impurity behavior in magnetically confined plasmas used in fusion plasmas. Recently, a space- and time-resolving flat-field grazing-incidence VUV spectrograph was constructed for the simultaneous observation of spatial, temporal, and spectral distributions of plasma radiation in the wavelength range of 150-1050 Å. Absolute calibration experiments were performed at beamline 11C and beamline 12A in the Photon Factory at the High Energy Acceleration Research Organization. The absolute sensitivity of the VUV spectrograph was measured under both P and S polarized light conditions.

UR - http://www.scopus.com/inward/record.url?scp=0035673333&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035673333&partnerID=8YFLogxK

U2 - 10.1063/1.1416105

DO - 10.1063/1.1416105

M3 - Article

AN - SCOPUS:0035673333

VL - 72

SP - 4366

EP - 4371

JO - Review of Scientific Instruments

JF - Review of Scientific Instruments

SN - 0034-6748

IS - 12

ER -